of the IDEA and to pay the excess costs of providing special education and related services to children with disabilities.52 Therefore, IDEA funds may be used only to pay for auxiliary aids...
Search Results "Positioning Aids"
-
19. Under what circumstances may a school district use IDEA funds to pay for auxiliary aids or services for IDEA‐eligible students to ensure effective communication as required by Title II?
- The Music of Life: Hearing Impairment PSA with Amanda Beers (Miss America Finalist)
-
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302
considering whether 1½ inches minimum clearance around the gripping surface would be appropriate for transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying position...
-
5.4.4 Transfer Support Distance from Transfer Surface Recommendations for M301 and M302
Surface Recommendations for M301 and M302 Description: This minimum distance ensures that the transfer support is within reach of the transfer surface and can be effectively used to position...
-
iv. Lifts
iv. Lifts Medical providers may need lifts to transfer some patients with mobility disabilities safely to examination or treatment tables or chairs or to gurneys or hospital beds....
-
DEFINITIONS
The term “Auxiliary Aids and Services” includes Qualified Interpreters on-site or through video remote interpreting (“VRI”) services; notetakers; real-time computer-aided transcription...
-
5.2.1.1 Transfer Surface Width
The transfer surface should be 28 inches wide minimum for equipment used by patients in a supine, side-lying, or prone position....
-
5.2.1.4 Transfer Surface Size for Imaging Equipment
5.2.1.4 Transfer Surface Size for Imaging Equipment. The transfer surface should be 28 inches wide minimum and 21 inches deep minimum. The transfer surface should be located such...
-
M301.2.2 Transfer Surface Size
M301.2.2 Transfer Surface Size Subcommittee Recommendation: (Also agreed to by the full committee). A. The minimum size of the transfer surface is 28 inches wide minimum and 21...
-
5.2.1.2 Transfer Surface Depth
The transfer surface should be 17 inches deep minimum for all equipment used by patients in a supine, side-lying, or prone position with the exception of imaging equipment....
-
M305.2.3 Height (Section-by-Section Analysis)
Additionally, for transfer surfaces that are greater than 24 inches deep, the MDE Advisory Committee recommended requiring a positioning support instead of a transfer support, with a height...
-
2.1.1 General Description
position....
-
11B-411.4.7 Designations and indicators of car control buttons
Designations and indicators of car control buttons shall comply with Section 11B-411.4.7.
-
11B-411.4.7 Designations and indicators of car control buttons
Designations and indicators of car control buttons shall comply with Section 11B-411.4.7.
-
Section 36.303 Auxiliary Aids and Services (Section-By-Section Analysis and Response to Comments)
As explained above, auxiliary aids and services are those aids and services required to provide effective communications....
-
(2) Transfer Surface Location for Diagnostic Equipment Used in the Seated Position
Commenters also raised concerns with the provisions in the MDE NPRM related to transferring to medical diagnostic equipment used by patients in the seated position....
-
M301.3.2 Stirrups
Where stirrups are provided, they shall provide a method of supporting, positioning, and securing the patient’s legs....
-
§35.130(b)(1)
(1) A public entity, in providing any aid, benefit, or service, may not, directly or through contractual, licensing, or other arrangements, on the basis of disability --...
-
§ 35.130(b)(1)
(1) A public entity, in providing any aid, benefit, or service, may not, directly or through contractual, licensing, or other arrangements, on the basis of disability—...
-
Gripping Surface Cross Section and Clearances M301, M302, and M305.2
Gripping Surface Cross Section and Clearances M301, M302, and M305.2 Gripping surface for transfer supports shall be free of sharp or abrasive elements and shall have rounded...
-
M305.2.2.1 End Transfer Supports
Transfer supports shall be positioned along 13 ½ inches (345 mm) minimum of the depth of the transfer surface....
-
M302.1 General
Where diagnostic equipment is used by patients in a seated position, it shall comply with M302....
-
§ 36.303 Auxiliary aids and services.
[See subsections ...]
-
M301.2.1 Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in the supine, prone, or side-lying position of 17 inches minimum and 19 inches maximum....