The MDE NPRM proposed that diagnostic equipment which could be used by patients in multiple positions must comply with the technical criteria for all positions in which it could be used...
Search Results "Positioning Aids"
Commonly Searched Documents
-
5. Exception from the Requirements of M302 for Weight Scales with Integral Seats
-
5.4.4.2 Transfer Support Distance from Transfer Surface for Imaging Equipment
Supports (transfer or positioning) should be located 1 ½ inches maximum from the transfer surface....
-
Features of Accessible Exam Tables
Exam surface lowers to 17” to 19” above the floor 4. 36” wide minimum accessible route 5.Exam surface may articulate to provide support during patient transfers and positioning...
-
How Can You Overcome These Barriers to Work with Your Providers?
There are many things that a person with a disability can do to improve his or her quality of health care and break down the barriers that compromise care. The following suggestions...
-
5.9 Standing Support Recommendations for M304 Diagnostic Equipment Used by Patients in a Standing Position
position and balance on diagnostic equipment used by patients in a standing position....
-
§ 36.303(d)(1)
an interactive voice response system, for receiving and directing incoming telephone calls, that system must provide effective real-time communication with individuals using auxiliary aids...
-
5.2.1.4 Transfer Surface Size Recommendations for Imaging Equipment (M301)
Manufacturers must determine the location of the transfer surface to facilitate the patient’s transfer and positioning for the clinical functions of the diagnostic procedure....
-
5.3.2.2 Transfer Sides Recommendation for Imaging Equipment
Recommendation for Imaging Equipment On imaging equipment, the transfer surface is oriented along the long dimension of the surface on which patients are in the supine, prone, or side-lying position...
-
5.7.1 Lift Compatibility Clearance in Base for Equipment Used by Patient in Supine, Prone, or Side-Lying Position
5.7.1 Lift Compatibility Clearance in Base for Equipment Used by Patient in Supine, Prone, or Side-Lying Position....
-
5.4.4.2 Transfer Support Distance from Transfer Surface Recommendation for Imaging Equipment
Distance from Transfer Surface Recommendation for Imaging Equipment The Committee recommends a maximum distance of 1 1/2 inches from the transfer surface to the support (either transfer or positioning...
-
i. Medical examination and treatment tables and chairs
i. Medical examination and treatment tables and chairs Healthcare providers use examination and treatment tables and chairs for many different types of medical and dental...
-
Chapter 3 Addendum: Title II Checklist (General Effective Communication)
Other Auxiliary Aids and Services 6. ...
-
3. Primary Consideration: Who Chooses the Auxiliary Aid or Service?
When an auxiliary aid or service is requested by someone with a disability, you must provide an opportunity for that person to request the auxiliary aids and services of their choice, and...
-
M301.2.1 Height
The transfer surface is permitted to be positioned outside of the specified height range when not needed to facilitate transfer....
-
11B-704.3 Volume control telephones
Public telephones with volume control shall be hearing aid compatible. [2010 ADA Standards] 704.3 Volume Control Telephones....
-
§ 38.125(d)(2) Wheelchair or mobility aid spaces
(2) Wheelchair or mobility aid spaces. Spaces for persons who wish to remain in their wheelchairs or mobility aids shall have a minimum clear floor space 48 inches by 30 inches....
- Phonic Ear HearIt Media Wireless Amplifier for Televisions and Mobile Telephones
-
M301.2.1 Adjustability
A low transfer position at a height of 17 inches (430 mm) minimum and 19 inches (485 mm) maximum; B. A high transfer position at 25 inches (635 mm); and C....
-
Paragraph (i) Hearing aid coupling (Section-by-Section Analysis)
Paragraph (i) Hearing aid coupling (Section-by-Section Analysis) No substantive comments were received on this provision and no changes were made, other than the editorial revisions discussed...
-
5.4.2.1 Transfer Support Length for Stretchers
5.4.2.1 Transfer Support Length for Stretchers. Transfer supports on stretchers should be a minimum of 15 inches long.
-
5.4.4.1 Transfer Support Distance from Transfer Surface Recommendation for Stretchers
5.4.4.1 Transfer Support Distance from Transfer Surface Recommendation for Stretchers The Committee recommends locating the transfer support along the long side of the of the...
-
5.3.2.1 Transfer Sides for Stretchers
5.3.2.1 Transfer Sides for Stretchers. The transfer surface shall be located to provide the ability to transfer from a mobility device onto both long sides of the surface.
-
5.4.4.1 Transfer Support Distance from Transfer Surface for Stretchers
5.4.4.1 Transfer Support Distance from Transfer Surface for Stretchers. Transfer supports should be located along the long side of the transfer surface on the opposite side of the...