Where equipment is designed to support more than one patient position, the equipment would have to meet the technical criteria for each position supported....
Search Results "Positioning Aids"
Commonly Searched Documents
-
4. Organization of Technical Criteria
-
Standing Supports (M304.3 and M305.3)
Standing supports can be provided in a horizontal position, vertical position, or a combination of horizontal and vertical positions, as long as the minimum length of gripping surface is...
-
Transfer Supports Location and Configuration M301.3 and M302.3
The length of the transfer support shall be a minimum of 15 inches long and positioned so that the transfer support overlaps the length of the transfer surface by 80% at a maximum distance...
-
19 Inch Low Height
Seats shall not be sprung to return to a lifted position.12 Likewise, 19 inch high benches are accessible: 903.5 Height....
-
5.2.2 Transfer Surface Size for Equipment Used by Patients in Seated Position
5.2.2 Transfer Surface Size for Equipment Used by Patients in Seated Position....
-
M301.3 Transfer Supports
Transfer Supports Position • Sub-Committee Recommendation: Located longitudinally within the long side of the of the transfer surface....
-
5.2.1.3 Transfer Surface Size for Stretchers
5.2.1.3 Transfer Surface Size for Stretchers. The transfer surface should be 28 inches wide minimum and 17 inches deep minimum located on both long sides of stretchers.
-
5.4.1.1 Transfer Support Location for Stretchers
5.4.1.1 Transfer Support Location for Stretchers. The transfer surface for stretchers should be oriented along the long side of the surface.
-
Communicating with People Who Have Disabilities
The ADA requires public entities to take the steps necessary to communicate effectively with people who have disabilities, and uses the term “auxiliary aids and services” to refer to readers...
-
III-4.3200 Effective communication
In order to provide equal access, a public accommodation is required to make available appropriate auxiliary aids and services where necessary to ensure effective communication....
-
Moving to the House Floor
He suggested that a vote against it would be a vote against small business—a position no member was eager to take.93 The bill would have put a finite dollar cap on accommodations....
-
How to Measure Transfer Surface Height
The corner radii allow for closer wheelchair positioning to facilitate independent transfer by minimizing gaps....
-
II-7.1100 Primary consideration.
The election procedures specify that an individual who requests assistance will be aided by two poll workers, or by one person selected by the voter....
-
Primary Consideration
Public entities are required to give primary consideration to the type of auxiliary aid or service requested by the person with the disability unless they can demonstrate that another equally...
-
M301.1 General (Section-by-Section Analysis)
The MDE NPRM proposed that all diagnostic equipment used by patients in a supine, prone, or side-lying position must comply with the technical requirements of proposed section M301....
-
Figure M3: Overview of M302 Diagnostic Equipment for Use by a Patient in a Seated Position
[See subsections ...]
-
§104.4(b)(1)(iv)
(iv) Provide different or separate aid, benefits, or services to handicapped persons or to any class of handicapped persons unless such action is necessary to provide qualified handicapped...
-
Companions in health care settings. (Section-by-Section Analysis)
It has been the Department's longstanding position that public accommodations are required to provide effective communication to companions when they accompany patients to medical care providers...
-
Receivers
Section 706.3 specifies that receivers required to be compatible with hearing aids (25%) must be neck loops since this type interfaces with hearing aid T-coils....
-
5.9 Standing Support for Equipment Used by Patients in a Standing Position
5.9 Standing Support for Equipment Used by Patients in a Standing Position....
-
Section 35.161 Telecommunications. (Section-by-Section Analysis)
In addition, commenters requested that the Department include ‘‘real-time'' before any mention of ‘‘computer-aided'' technology to highlight the value of simultaneous translation of any...
-
5. Exception from the Requirements of M302 for Weight Scales with Integral Seats
The MDE NPRM proposed that diagnostic equipment which could be used by patients in multiple positions must comply with the technical criteria for all positions in which it could be used...
-
5.4.4.2 Transfer Support Distance from Transfer Surface for Imaging Equipment
Supports (transfer or positioning) should be located 1 ½ inches maximum from the transfer surface....
-
Features of Accessible Exam Tables
Exam surface lowers to 17” to 19” above the floor 4. 36” wide minimum accessible route 5.Exam surface may articulate to provide support during patient transfers and positioning...