Doors along an accessible route shall comply with 4.13....
Search Results "Compartment Door"
Commonly Searched Documents
-
4.3.9 DOORS
-
4.3.9 Doors
Doors along an accessible route shall comply with 4.13....
-
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
Doors
[See subsections ...]
-
11B-604.2 Location
side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment...
-
11B-605.5.2 Maneuvering clearance
A turning space complying with Section 11B-304 shall be provided within the compartment....
-
11B-604.2 Location
side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment...
-
11B-604.2 Location
side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment...
-
11B-407.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-407.3....
-
11B-407.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-407.3....
-
11B-407.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-407.3....
-
11B-809.4.1 Subsequent bathrooms
In residential dwelling units with more than one bathroom, when a bathtub is installed in the first bathroom in compliance with Section 11B-809.4 and a shower compartment is provided in...
-
4.13.9* DOOR HARDWARE
When sliding doors are fully open, operating hardware shall be exposed and usable from both sides....
-
Door and Gate Hardware
Section 404.2.7 also covers the operating characteristics and height of door and gate hardware....
-
11B-213.3.1 Toilet compartments
SECTION TITLE NOTES 11B-213.3.1 Toilet compartments Corrects drafting error...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-411.3.5 Width
The width of elevator doors shall comply with Table 11B-407.4.1....
-
Doors in a Series
A few commenters expressed concern that the Guidelines did not provide design for an entrance that consists of a series of more than one door....
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
Is compliance on both sides of a door or gate required when it is usable only from one side?
No, compliance is not required on both sides of those doors or gates that can be used in one direction only. Compliance is required only on the usable side....
-
1991 / 1994 ADA Standards - Plan Review Tool - Doors
1991 / 1994 ADA Standards - Plan Review Tool - Doors Click here to view/download the pdf, Page 1 of 2 (256 KB) Click here to view/download the pdf, Page 2 of 2 (272 KB) * * * *...
-
604.2 Location
side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment...