Operable parts include light switches, electrical and communication receptacles, thermostats, alarm pulls, automatic door controls, and other elements used by facility occupants....
Search Results "Non-Fixed Element"
-
Operable Parts Covered [§205]
-
[A] BUILDING
Rather, these elements are generally considered to be facilities. See the definition of FACILITY.◼...
-
BUILDING
Rather, these elements are generally considered to be facilities. See the definition of FACILITY. ◼...
-
306.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...
- USDA Forest Service Built Environment Image Guide (BEIG)
-
ACTIONS TO BE TAKEN BY CAMP BRAVO
Camp Bravo will adopt, maintain, and enforce the non-discrimination statement attached hereto and incorporated by reference herein as Exhibit 1 to this Agreement. ...
-
M305.2.4 Cross Section (Section-by-Section Analysis)
Specifically, the Access Board indicated it was considering requiring circular cross sections to have an outside diameter of 1¼ inches minimum and 2 inches maximum, and transfer supports with non-circular...
-
3.7 Louisville Tinseltown 19, 4400 Towne Center Drive, Louisville, Kentucky
- In Auditoria 2, 3, 5, 8, 12, 15, 17, and 18 one fixed companion seat shall be provided next to each wheelchair space....
-
1115B.4.5, Item 5
A shower spray unit with a hose at least 60 inches (1524 mm) long that can be used both as a fixed shower head and as a hand-held shower shall be provided....
-
5.1.3 Transfer Surface Low Height Options for M301 and M302
The Committee shifted focus from a fixed height range between 17 to 19 inches as adjustability was accepted....
-
Portable tactile maps
Regardless of the technique employed, the major drawback of portable tactile maps is they lack a fixed point of reference, or a You Are Here marker....
-
Samsung Authorized Service Center Abu Dhabi For Quality Repairs And Expert Assistance
Instead of relying on temporary fixes, customers can seek a proper assessment to determine whether a component needs adjustment, replacement, or further testing....
-
C. Developing an Action Plan For Providing Accessible Websites
The next steps are to develop an action plan to fix web content that is currently inaccessible and implement procedures to ensure that all new and modified web content is accessible....
-
New Construction and Alterations
Alterations to facilities, spaces or elements (including renovations) on or after January 26, 1992, also must comply with the Standards....
-
11B-225.3 Self-service storage facilities
Although there are no technical requirements that are unique to self-service storage facilities, elements and spaces provided in facilities containing self-service storage spaces required...
-
F225.3 Self-Service Storage Facilities
Although there are no technical requirements that are unique to self-service storage facilities, elements and spaces provided in facilities containing self-service storage spaces required...
-
5.4.9 Interruptions along Transfer Support Gripping Recommendation for M301 and M302
5.4.9 Interruptions along Transfer Support Gripping Recommendation for M301 and M302 Description: Transfer supports may contain elements to provide structural support or prevent patient...
-
R302.7 Surfaces
The surfaces of pedestrian access routes and elements and spaces required to comply with R302.7 that connect to pedestrian access routes shall be firm, stable, and slip resistant and shall...
-
R204.2 Sidewalks
The pedestrian access route shall connect to accessible elements, spaces, and facilities required by this document and to accessible routes required by section 206.2.1 of appendix B to 36...
-
11B-225.3 Self-service storage facilities
Although there are no technical requirements that are unique to self-service storage facilities, elements and spaces provided in facilities containing self-service storage spaces required...
-
101.1 General
This document contains scoping and technical requirements for accessibility to sites, facilities, buildings, and elements by individuals with disabilities....
-
225.3 Self-Service Storage Facilities
Although there are no technical requirements that are unique to self-service storage facilities, elements and spaces provided in facilities containing self-service storage spaces required...
-
225.3 Self-Service Storage Facilities
Although there are no technical requirements that are unique to self-service storage facilities, elements and spaces provided in facilities containing self-service storage spaces required...
-
Path of Travel
interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms, and other improved areas; parking access aisles; elevators and lifts; or a combination of these elements...