The transfer surface shall be 21 inches (610 mm) wide minimum and 15 inches (381 mm) deep minimum. Advisory M302.2.2 Size....
Search Results "Side Transfer Surface"
Commonly Searched Documents
-
M302.2.2 Size
-
5.4.6 Transfer Support Gripping Surface Cross Section and Clearances for M301, M302, and M305.2
5.4.6 Transfer Support Gripping Surface Cross Section and Clearances for M301, M302, and M305.2 Description: This provision prescribes a cross-sectional profile of the transfer support...
-
11B-1008.4.5 Transfer supports
Where play components require transfer to entry points or seats, at least one means of support for transferring shall be provided....
-
11B-1008.4.5 Transfer supports
Where play components require transfer to entry points or seats, at least one means of support for transferring shall be provided....
-
11B-1008.4.5 Transfer supports
Where play components require transfer to entry points or seats, at least one means of support for transferring shall be provided....
-
Transfer Supports
Transfer Supports A means of support is required when transferring into the entry or seat of a play component....
-
M305.2.3 Height (Section-by-Section Analysis)
transfer surface would be usable by patients with disabilities....
-
How To Transfer from a Wheelchair to Hospital Bed (Stretcher) with a Sliding Board
Requires the Registered User plan or above. Login!
-
11B-406.5.4 Floor or ground surfaces
Floor or ground surfaces of curb ramps and blended transitions shall comply with Section 11B-405.4....
-
11B-407.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Section 11B-302 and 11B-303....
-
Transfer Access [1014.2.1]
To provide transfer access at the entrance to a camp shelter, a clear ground space at least 36 by 48 inches positioned for a parallel approach must be provided along the open side of the...
-
11B-1002.6.2 Transfer height
The height of transfer device seats shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
11B-406.2.2 Sides of curb ramps
Where provided, curb ramp flares shall not be steeper than 1:10.
-
11B-406.2.2 Sides of curb ramps
Where provided, curb ramp flares shall not be steeper than 1:10.
-
Surfaces
An accessible surface is firm and stable. Use caution with the size and depth of gravel when maintaining unpaved surfaces....
-
Dining Surfaces and Work Surfaces for Children's Use: ADA Standard Section 902.4
Accessible dining surfaces and work surfaces for children’s use shall comply with 902.4....
-
Highest and Lowest Heights Obtained
These data represent the ability of the participants in the study to complete a transfer....
-
Walking Surfaces: ADA Standard Section 403
Section 403 covers the current ADA Standards for walking surfaces that are part of an accessible route.
-
M305.2.3 Height
During use, the tops of transfer support gripping surfaces shall be 6 inches (150 mm) minimum and 19 inches (485 mm) maximum higher than the top of the associated uncompressed transfer surface...
-
Transfer Demonstration from Wheelchair to Bed and Back to Wheelchair
Requires the Registered User plan or above. Login!
-
Floor or Ground Surfaces: ADA Standard Section 305.2
Section 305.2 covers the current ADA Standards for floor or ground surfaces of clear floor or ground space.
-
Adjustable Height Range Considered
Transfer surfaces that are adjustable to the same heights as the seat heights of mobility devices reduce the effort needed to transfer since patients do not have to lift their body weight...
-
M305.2.1 Location
Transfer supports shall be located within reach of the transfer surface and shall not obstruct transfer onto or off of the surface when in position....