Section 410.2 covers the current ADA Standards for floor surfaces in platform lifts.
Search Results "Side Transfer Surface"
Commonly Searched Documents
-
Floor Surfaces: ADA Standard Section 410.2
-
308.3 Side Reach
308.3 Side Reach...
-
308.3 Side Reach
308.3 Side Reach....
-
308.3 Side Reach
308.3 Side Reach....
-
Chapter 3: Study findings
[See subsections ...]
-
10. Can a transfer platform be an irregular shape as long as it incorporates the minimum rectangle of 14 by 24 inches?
Can a transfer platform be an irregular shape as long as it incorporates the minimum rectangle of 14 by 24 inches? Yes....
-
11B-608.3.1 Transfer type shower compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (457 mm) from the control wall....
-
Grab Bars: ADA Standard Section 1009.5.7
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above each step and transfer platform....
-
11B-1009.5.7 Grab bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (102 mm) minimum and 6 inches (152 mm) maximum above each step and transfer platform....
-
3.3.15.2 Side (lateral) reach - unobstructed
3.3.15.2 Side (lateral) reach - unobstructed For WhMD users in our study that could perform a reach task, over 90% of each of the WhMD user groups could reach beyond the lateral most...
-
11B-404.2.11 Vision lights
Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel...
-
11B-403 Walking surfaces
[See subsections ...]
-
1009.5 Transfer Systems
Transfer systems shall comply with 1009.5....
-
1009.4 Transfer Walls
Transfer walls shall comply with 1009.4....
-
1009.4 Transfer Walls
Transfer walls shall comply with 1009.4....
-
1009.5 Transfer Systems
Transfer systems shall comply with 1009.5....
-
13.13 Permitted Transfer
13.13 “Permitted Transfer” means one of the following:...
-
Height: ADA Standard Section 1008.3.1.2
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
General: ADA Standard Section 1009.1
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with 1009....
-
Dining Surfaces and Work Surfaces: ADA Standard Section 902
[See subsections ...]
-
Dining Surfaces and Work Surfaces: ADA Standard Section 226
Section 226 covers scoping requirements in the current ADA Standards for dining surfaces and work surfaces.
-
11B-1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with Section 11B-1009....
-
11B-1008.3.2.3 Transfer supports
At least one means of support for transferring shall be provided. [2010 ADAS] Advisory 1008.3.2.3 Transfer Supports. ...