The size and arrangement of the standard toilet stall shall comply with Fig. 30(a), Standard Stall. Standard toilet stalls with a minimum depth of 56 in (1420 mm) (see Fig. 30(a))...
Search Results "Maximum Dimension"
-
4.17.3* Size and Arrangement
-
11B-222.1 General
Where dressing rooms, fitting rooms, or locker rooms are provided, at least 5 percent, but no fewer than one, of each type of use in each cluster provided shall comply with Section...
-
11B-222.1 General
Where dressing rooms, fitting rooms, or locker rooms are provided, at least 5 percent, but no fewer than one, of each type of use in each cluster provided shall comply with Section...
-
222.1 General
Where dressing rooms, fitting rooms, or locker rooms are provided, at least 5 percent, but no fewer than one, of each type of use in each cluster provided shall comply with...
-
222.1 General
222.1 General. Where dressing rooms, fitting rooms, or locker rooms are provided, at least 5 percent, but no fewer than one, of each type of use in each cluster provided shall comply...
- Selenia Dimensions Mammography System
-
Conclusion
path of travel) readily accessible to and usable by individuals with disabilities, including individuals who use wheelchairs, without regard to cost or cost disproportionality, to the maximum...
-
11B-703.3.1 Dimensions and capitalization
TABLE 11B-703.3.1 BRAILLE DIMENSIONS MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES Dot base diameter...
-
11B-703.3.1 Dimensions and capitalization
TABLE 11B-703.3.1 BRAILLE DIMENSIONS MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES Dot base diameter...
-
21. New construction
The phrase “to the maximum extent feasible” has been added to allow for the occasional case in which the nature of an existing facility is such as to make it impractical or prohibitively...
-
11B-232.2.1.4 Technically infeasible
Where it is technically infeasible to locate a substitute cell within the same prison site in compliance with Section 11B-232.2.1.3, a substitute cell shall be provided at another...
-
11B-232.2.1.4 Technically infeasible
Where it is technically infeasible to locate a substitute cell within the same prison site in compliance with Section 11B-232.2.1.3, a substitute cell shall be provided at another...
-
Sec.36.403(a) General
An alteration that affects or could affect the usability of or access to an area of a facility that contains a primary function shall be made so as to ensure that, to the maximum extent...
-
Alterations to Residential Facilities
Alterations to Residential Facilities. Section 4.1.6 of the UFAS requires federal, state, and local government housing to comply with the general requirements for alterations to...
-
Fire Rings, Grills, Fireplaces, and Woodstoves [1011.2, 1011.3, and 1011.5]
A minimum of 48 by 48 inches of clear ground space must be provided on all usable sides of fire rings, grills, fireplaces, and woodstoves. The usable sides of these elements are the...
-
Alterations and Additions
Alterations and Additions When a building or facility is renovated or altered or added to for any purpose, the alterations or additions must comply with the ADA Standards. In...
-
A4.2.5 & A4.2.6 Reach
Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a). These drawings approximate in the plan view the information shown in Fig. 4, 5, and...
-
A4.2.5 & A4.2.6 REACH
Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a). These drawings approximate in the plan view information shown in Fig. 4, 5, and 6 in other...
-
3. New Construction vs. Alterations
In these cases, the curb ramps installed must meet the accessibility requirements of the ADA to the maximum extent feasible.10 Scoping requirements in the ADA Standards establish limitations...
-
4.3 Reach Ranges
They specify maximum and minimum heights but do not take into consideration the fact that the depth and height of the obstruction can vary with a corresponding impact on the reach envelope...
-
Path of travel
The path of travel to the altered or added portion of the facility must be made accessible, to the maximum extent feasible....
-
11B-810.2.2 Dimensions
Transportation's ADA Standards indicate that compliance is required to the extent construction specifications are within a public entity's control: [ADA Title II - Public Transportation] 810.2.2 Dimensions...
-
11B-810.2.2 Dimensions
Transportation's ADA Standards indicate that compliance is required to the extent construction specifications are within a public entity's control: [ADA Title II - Public Transportation] 810.2.2 Dimensions...
-
F202.2.3 Toilet and Bathing Facilities
Where toilet facilities and bathing facilities are not provided in an addition but are provided in the existing building or facility to serve the addition, the toilet facilities and...