Where the turning space has two entrance/exit points other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep at both entrance/ exit points, as measured...
Search Results "Approach Enter Exit"
-
11B-705.1.2.2.2.2 Two entrance/exit points
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
-
11B-407.4.6.1 Location
Exceptions: Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm)...
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
-
11B-407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the...
-
11B-407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the...
-
4.31.3* Mounting Height
The highest operable part of the telephone shall be within the reach ranges specified in 4.2.5 or 4.2.6.
-
III-6.2000 Alterations: Path of travel
III−6.2000 Alterations: Path of travel. When an alteration is made to a "primary function area," not only must that alteration be done in compliance with ADAAG, but there must also...
-
Is clear floor space required to be centered on elements?
The standards require the clear floor space to be centered on wheelchair accessible drinking fountains (forward approach), kitchen work surfaces, (forward approach), and washers and dryers...
-
11B-809.8.1 Door Thresholds
Primary entry doors, required exit doors, and interior doors intended for user passage shall have thresholds complying with Section 11B-404.2.5....
-
I1b
For a front approach (where clear floor space at least 30 inches wide x 48 inches long), is the coin slot no higher than 48 inches above the floor?...
-
Clear Floor Space [§309.2]
Clear Floor Space [§309.2] Clear floor space for forward approaches must extend up to or, if knee or toe space is provided, below operable parts....
-
Clear Floor Space [4.18.3]
Clear Floor Space [4.18.3] Clear floor space at least 30 inches wide is required, including between partitions where they are provided (when shields do not extend beyond the front...
-
Knee and Toe Space Depth
[See subsections ...]
-
1009.4 Elevators
In order to be considered part of an accessible means of egress, an elevator shall comply with Sections 1009.4.1 and 1009.4.2.
-
1009.4 Elevators
In order to be considered part of an accessible means of egress, an elevator shall comply with Sections 1009.4.1 and 1009.4.2.
-
Knee and Toe Clearance: ADA Standard Section 305.4
Section 305.4 covers the current ADA Standards for knee and toe clearance included in clear floor space.
-
A4.3.11.3 Stairway Width
A 48 in (1220 mm) wide exit stairway is needed to allow assisted evacuation (e.g., carrying a person in a wheelchair) without encroaching on the exit path for ambulatory persons....
-
907.2.9 Group R-2
A fire alarm system shall be installed in Group R-2 occupancies where: Any dwelling unit is located three or more stories above the lowest level of exit discharge; Any...
-
1009.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
1009.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, not less than one required accessible means of egress shall be an elevator...
-
4.7.9.2 Clear Floor or Ground Space
Clear floor or ground space 48 inches (1220 mm) by 30 inches (760 mm) oriented for a forward or parallel approach shall be provided for utility sinks required to meet 4.7.9....
-
1007.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...