- Figure 404.2.4.1(b) Maneuvering Clearances at Manual Swinging Doors and Gates: Front Approach, Push Side – Drawing from the U.S. Access Board
-
1007.2, Item 7
Horizontal exits complying with Section 1025....
-
1009.2, Item 7
Horizontal exits complying with Section 1026....
-
Approach and Maneuvering Clearance [§305.6 and §305.7]
Approach and Maneuvering Clearance [§305.6 and §305.7] Where the space is obstructed on both sides for more than half the depth, additional clearance is required for maneuvering....
-
Accessible Means of Egress: ADA Standard Section 207
Section 207 covers scoping requirements in the most current ADA Standards for accessible means of egress.
- Figure 404.2.4.1(c) Maneuvering Clearances at Manual Swinging Doors and Gates: Front Approach, Push Side with Closer and Latch – Drawing from the U.S. Access Board
- Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach – Drawing from the U.S. Access Board
- Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach – Drawing from the U.S. Access Board
-
Clear Floor Space: ADA Standard Section 606.2
Section 606.2 covers the current ADA Standards for clear floor space at lavatories and sinks.
-
1007.2, Item 2
Interior exit stairways complying with Sections 1007.3 and 1022, and Chapter 11A, Section 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
1009.2, Item 2
Interior exit stairways complying with Sections 1009.3 and 1023, and Chapter 11A, Section 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
1007.2, Item 3
Interior exit access stairways complying with Sections 1007.3 and 1009.3, Chapter 11A, Section 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
1009.2, Item 3
Exit access stairways complying with Sections 1009.3 and 1019.3 or 1019.4, Chapter 11A, Section 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
11B-805.2.2 Beds
The clear floor space shall be positioned for parallel approach to the side of the bed....
-
11B-805.2.2 Beds
The clear floor space shall be positioned for parallel approach to the side of the bed....
-
1009.3.3 Area of Refuge
Exceptions: Areas of refuge are not required at exit access stairways where two-way communication is provided at the elevator landing in accordance with Section 1009.8....
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm).
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm).
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm).
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm).
-
605.3 Clear Floor Space
A clear floor or ground space complying with 305 positioned for forward approach shall be provided....
- ADA Sign Depot Exit Stair Down Sign - 6" x 6" - Tactile Text and Grade 2 Domed Braille
-
11B-605.3 Clear floor space
A clear floor or ground space complying with Section 11B-305 positioned for forward approach shall be provided....