Search Results "Approach Enter Exit"
-
Knee and Toe Space Depth
-
1007.6 Areas of refuge
is used as an area of refuge, the shaft and lobby shall comply with Section 1019.1.8 for smokeproof enclosures except where the elevators are in an area of refuge formed by a horizontal exit...
-
Knee and Toe Clearance: ADA Standard Section 305.4
Section 305.4 covers the current ADA Standards for knee and toe clearance included in clear floor space.
-
1132A.1 Primary entry doors and required exit doors
The width and height of primary entry doors and all required exit doors shall comply with Section 1126A.1....
-
1132A.1 Primary entry doors and required exit doors
The width and height of primary entry doors and all required exit doors shall comply with Section 1126A.1....
-
4.7.9.2 Clear Floor or Ground Space
Clear floor or ground space 48 inches (1220 mm) by 30 inches (760 mm) oriented for a forward or parallel approach shall be provided for utility sinks required to meet 4.7.9....
- Access Board: Parallel Approach at an Alcove
- Access Board: Forward Approach at an Alcove
-
4. Desk with knee and toe space
Desk with knee and toe space and clear floor space for front approach....
-
11B-606.7 Sink depth
Where a forward approach is required at a sink, knee and toe clearance shall be provided in compliance with Section 11B-306....
-
11B-606.7 Sink depth
Where a forward approach is required at a sink, knee and toe clearance shall be provided in compliance with Section 11B-306....
-
11B-809.9.1 Clear floor space
48 inches (1219 mm), with centerlines aligned with the centerline of the work surface, appliance, sink or fixture, shall be provided in the following locations: For a parallel approach...
-
11B-606.7 Sink depth
Where a forward approach is required at a sink, knee and toe clearance shall be provided in compliance with Section 11B-306....
-
4.16.2 Clear Floor Space
Clear floor space may be arranged to allow either a left-handed or right-handed approach....
-
1003.2.13.5 Areas of refuge
used as an area of refuge, the shaft and lobby shall comply with Section 1005.3.2.5 for smokeproof enclosures except where the elevators are in an area of refuge formed by a horizontal exit...
-
Approach: ADA Standard Section 1002.4.6
One side of the wheelchair space shall adjoin an accessible route when in the load and unload position.
-
1009.2 Continuity and components
Interior exit stairways complying with Sections 1009.3 and 1023, and Chapter 11A, Section 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
9.3 SELF-SERVICE POSTAL CENTER
All mechanisms must be installed to permit close parallel approach by a wheelchair user....
-
4.16.2 CLEAR FLOOR SPACE
Clear floor space may be arranged to allow either a left-handed or right-handed approach....
-
Clear Floor Space: ADA Standard Section 602.2
Section 602.2 covers the current ADA Standards for drinking fountain clear floor space.
-
4.15.5(2)
or built-in units not having a clear space under them shall have a clear floor space at least 30 in by 48 in (760 mm by 1220 mm) that allows a person in a wheelchair to make a parallel approach...
-
4.15.5(2)
or built-in units not having a clear space under them shall have a clear floor space at least 30 in by 48 in (760 mm by 1220 mm) that allows a person in a wheelchair to make a parallel approach...
-
11B-602.2 Clear floor space
Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....
-
11B-602.2 Clear floor space
Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....