Windows requiring pushing, pulling, or lifting to open (for example, double-hung, sliding, or casement and awning units without cranks) should require no more than 5 lbf (22.2 N) to open...
Search Results "End-Opening Door"
-
A4.12.2 Window Hardware
-
II. Systemic Considerations
Training criminal justice personnel, conducting reviews of policies and procedures, and collaborating with mental health and disability services providers are three ways to achieve that end...
- Pilot Rock T-600 Series Caterpillar Picnic Table
-
4.34.6.10* KITCHEN STORAGE
(2) Door pulls or handles for wall cabinets shall be mounted as close to the bottom of cabinet doors as possible....
-
Section 2. Entrance
For purposes of these guidelines, an "entrance" does not include a door to a loading dock or a door used primarily as a service entrance, even if nonhandicapped residents occasionally use...
-
Bench: ADA Standard Section 612.2
Section 612.2 covers the current ADA Standards for benches in saunas and steam rooms.
-
704.2.3 Combustible projections
Combustible projections located where openings are not permitted or where protection of openings is required shall be of at least 1-hour fire-resistance-rated construction, Type IV construction...
-
11B-809.10.6.1 Size
unit, as least one shower stall shall comply with one of the following: A transfer type shower compartment 36 inches (914 mm) wide by 36 inches (914 mm) deep with an entrance opening...
- AJW Architectural Products U6084 Unidoor Folded Towel Dispenser & Waste Receptacle Combination - Recessed
- Pilot Rock BPR1 Bear Resistant Trash Receptacle
-
Sloped Surfaces
Rest one end of the level at the highest point of the sloped surface and lift the other end (see image) until the bubble is in the middle of the tube. This is the "level" position....
-
Observations:
The wheelchair scale we used had a leveled surface of length 30 in. long with a bevel of 5 in. each at both ends (i.e., total length of 40 in.)....
-
11B-104.1.1 Construction and manufacturing tolerances
All dimensions are subject to conventional industry tolerances except where the requirement is stated as a range with specific minimum and maximum end points....
-
11B-104.1.1 Construction and manufacturing tolerances
All dimensions are subject to conventional industry tolerances except where the requirement is stated as a range with specific minimum and maximum end points....
-
§ 36.303(g)(6)(ii)
(ii) A public accommodation may use open movie captioning as an alternative to complying with the requirements specified in paragraph (g)(3) of this section, either by providing open movie...
- Door King Inc. 6004 Column Mount Swing Gate Operator
- Door King Inc. VoIP Integration for Entry and Access Control Systems
- Jacknob Corp. 6409 ADA Latch & Strike Combo for Inswinging Door
-
704.10 Vertical exposure
For buildings on the same lot, approved protectives shall be provided in every opening that is less than 15 feet (4572 mm) vertically above the roof of an adjoining building or adjacent...
- Pilot Rock BPR2 Bear Resistant Trash and Recycling Receptacle
- AJW Architectural Products U5814 Unidoor 1.5 Gallon Sanitary Napkin Disposal - Recessed
-
11B-1004.1 Clear floor space
To optimize space use, designers should carefully consider layout options such as connecting ends of the row and center aisle spaces....
-
11B-1004.1 Clear floor space
To optimize space use, designers should carefully consider layout options such as connecting ends of the row and center aisle spaces....