(b) Before any Newly Constructed Hotel is open to the public after the Effective Date, HWI will require the hotel owner to provide a certification from an architect that includes the following...
Search Results "End-Opening Door"
Commonly Searched Documents
-
18(b)
-
II-7.3300 Seven-digit lines.
[Insert the following text at the end of this section, p. 42.]...
-
609.3 Spacing
The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
609.3 Spacing
The space between the grab bar and projecting objects below and at the ends shall be 1 1/2 inches (38 mm) minimum....
-
Appendix A to Part 35
the preamble to the final regulation on nondiscrimination on the basis of disability in State and local government services beginning at the heading "Section-by- Section Analysis" and ending...
-
11B-806.2.3.1 Personal lift device floor space
The clear space shall extend to points horizontally 30 inches (762 mm), vertically 7 inches (178 mm) and not more than 12 inches (305 mm) from the head and foot end of the bed....
-
609.3 Spacing
The space between the grab bar and projecting objects below and at the ends shall be 1 1/2 inches (38 mm) minimum....
-
11B-610.2 Bathtub seats
Permanent seats at the head end of the bathtub shall be 15 inches (381 mm) deep minimum and shall extend from the back wall to or beyond the outer edge of the bathtub....
-
11B-806.2.3.1 Personal lift device floor space
The clear space shall extend to points horizontally 30 inches (762 mm), vertically 7 inches (178 mm) and not more than 12 inches (305 mm) from the head and foot end of the bed....
-
11B-304.3.2 T-Shaped space
The space shall be permitted to include knee and toe clearance complying with Section 11B-306 only at the end of either the base or one arm. ...
-
11B-806.2.3.1 Personal lift device floor space
The clear space shall extend to points horizontally 30 inches (762 mm), vertically 7 inches (178 mm) and not more than 12 inches (305 mm) from the head and foot end of the bed....
-
11B-304.3.2 T-Shaped space
The space shall be permitted to include knee and toe clearance complying with Section 11B-306 only at the end of either the base or one arm....
-
11B-606.4 Faucets
Hand-operated metering faucets shall remain open for 10 seconds minimum....
-
4.3.11.1(3)
(3) A portion of a one-hour fire-resistive corridor (complying with local requirements for fire-resistive construction and for openings) located immediately adjacent to an exit enclosure...
-
Preliminary Guidelines for SEWF Installation
Read material safety data sheets carefully prior to opening containers. Wear protective clothing and eye gear at all times....
-
404.2.11 Vision Lights
Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel...
-
§ 37.3 Origin-to-destination service
A provider may provide ADA complementary paratransit in a curb-to-curb or door-to-door mode....
-
1130A.1 General
The accessible route shall pass through the primary entry door, and shall connect with all additional exterior doors, required clear floor spaces at kitchen appliances and bathroom fixtures...
-
1130A.1 General
The accessible route shall pass through the primary entry door, and shall connect with all additional exterior doors, required clear floor spaces at kitchen appliances and bathroom fixtures...
-
Expert Report of Ken Schoonover, P.E., KMS Associates, Inc. (August 7, 2018)
Hallways & Corridors: The interior door cannot be opened with 5 pounds of force or less (1991 ADA Stds 4.13.11; 2010 ADA Stds 404.2.9)....
-
Requirements for Platform Lifts
Platform Lift Clear Floor Space and Doors/ Gates...
-
GUARD [DSA-AC, HCD 1, HCD 2 & HCD 1-AC] OR GUARDRAIL
A building component or a system of building components located at or near the open sides of elevated walking surfaces that minimizes the possibility of a fall from the walking surface to...
-
11B-803.1 General
Partitions and doors should be designed to ensure people using accessible dressing and fitting rooms privacy equivalent to that afforded other users of the facility....
-
Additional benefits of water closet clearance standards
To make these calculations, the Department separated out toilet rooms with out-swinging doors from those with in-swinging doors, because the costs and benefits of the respective water closet...