Search Results "Floor Designation"
Commonly Searched Documents
- BEA Inc. LZR-Microscan Swinging Door Sensor
-
I. BACKGROUND
The project design phase for the Middletown Road Station renovations was completed by an NYCTA design team in 2007. Pls.’ Responses ¶ 29....
-
General: ADA Standard Section 308.1
Section 308.1: of the ADA Standards covers information in the current ADA Standards for reach ranges.
-
11B-809.9.2 Clear width
U-shaped kitchens, designed with parallel approach at a sink, range, cooktop or other fixtures and appliances located at the base of the U without knee and toe clearance, shall provide a...
-
11B-308.1 General
The following table provides guidance on reach ranges for children according to age where building elements such as coat hooks, lockers, or operable parts are designed for use primarily...
- DORMA BTS80 EMB Series Door Closer
- Magnuson Group WH Hanger Style Wall Rack
- Cavity Sliders USA Inc. CL100 ADA Privacy Lever Lock for Pocket Doors
-
4.2.6* Side Reach
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
4.34.6.4(4)
(4) A clear floor space 30 in by 48 in (760 mm by 1220 mm) shall allow a forward approach to the counter....
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
-
5.1 Architectural Barriers Act (ABA).
following ABA requirements apply to recipients of federal financial assistance from DOT: 5.1.1 ATBCB Final Rule, 36 CFR part 1190, Minimum Guidelines and Requirements for Accessible Design...
-
11B-104.1.1 Construction and manufacturing tolerances
Recognized tolerances are not intended to apply to design work. It is good practice when specifying dimensions to avoid specifying a tolerance where dimensions are absolute....
-
Selection of Variables
small anthropometric survey is a costly undertaking and if it is to be done, the addition of a reasonable number of variables for which there will clearly be other uses, such as wheelchair design...
-
308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side...
-
Bedside Clearance [9.2.2(1)]
Clear floor space is required at accessible controls and elements (e.g., thermostats), storage facilities (e.g., closets), and should be provided at non-fixed furnishings (e.g., dressers...
-
Appendix Three: Bibliography
Space Requirements for Wheeled Mobility Devices in Public Transportation: Analysis of Clear Floor Space Requirements....
-
Waviness Index
Waviness Index The Waviness Index, ASTM E 1486, Standard Test Method for Determining Floor Tolerances Using Waviness, Wheel Path and Levelness Criteria, was developed in response to the...
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of the partition...
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of the partition...
-
11B-411.2.1.4.1.2 Identification
Identification shall be placed immediately to the left of the control button to which the designation applies....
-
C. Toilet Rooms:
For any inaccessible suite toilet room and multi-user toilet room, PSE shall provide directional signage indicating the location of the designated accessible toilet rooms on the same level...
-
Obstructed High Reach: ADA Standard Section 308.2.2
Section 308.2.2 covers the current ADA Standards for obstructed high reach.
-
11B-411.2.1.7.3 Assignment by security credential
Upon presentation of security credential, the destination floor shall be confirmed by verbal announcement and on the display screen....