11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
-
611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor....
-
410 Platform Lifts
Section 410 provides requirements for platform lifts and addresses floor surfaces, clear floor space, operable parts, and doors and gates....
-
Main Lobby
The 40 1/2" height of the main ticket counter exceeds the maximum allowable height of 36" above the finished floor. See Standards § 7.2(1). j....
-
Accessible Route
Interior accessible routes may include corridors, floors, ramps, elevators, lifts, and clear floor space at fixtures....
-
Scoping [4.1.3(10)]
Instead it requires access based on the number provided on each floor so that half (50%) are accessible to people who use wheelchairs....
-
Dispersion
For example, if a floor is occupied by separate tenancies, both types of units should be dispersed to serve occupants of each tenancy....
-
4.2.6* SIDE REACH
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
III-7.5140 Drinking fountains
Where there is only one drinking fountain on a floor, it must be accessible both to individuals who use wheelchairs and to those who have difficulty bending or stooping (for example, by...
- Hoyer Presence Heavy-Duty Lift
-
206.2.3 Multi-Story Buildings and Facilities
However, if the laundry room on the first floor is restricted to use by residents on the first floor, and the second floor laundry room is for use by occupants of the second floor, then...
-
Equipment and furniture. (Section-by-Section Analysis)
These groups recommended that the Department list by name certain types of medical equipment that must be accessible, including exam tables (that lower to 15 inches above the floor or lower...
-
Background
Over the last decade, accessibility standards have also expanded and the number of seating surfaces designed for transfer has increased to more elements designed for transferring to elements...
-
1134A.6, Item 4
Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
-
407.4.8.2.1 Signal Type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor....
-
4.7.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
1134A.6, Item 4
Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
-
11B-809.10.6.4 Reinforcement for grab bars
grabs bars shall comply with the following: Continuous reinforcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm) minimum above the finish floor...
-
11B-608.5.3 Alternate roll-in type shower compartments
The controls, faucets, and shower spray units shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor....
-
BHMA
Builders Hardware Manufacturers’ Association 355 Lexington Avenue, 15th Floor New York, NY 10017-6603 A 156.10-2017: Power Operated Pedestrian Doors 11B-404.2.9, 11B-404.3...