Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
Search Results "Floor Designation"
-
11B-306.3.4 Clearance reduction
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar with the opening of the disposal unit 19 inches minimum (483 mm) above the finish floor....
-
11B-407.2.1.1 Height
[2010 ADA Standards] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline...
-
Edge Protection: ADA Standard Section 1005.3
Extending the deck of the fishing pier or platform 12 inches (305 mm) where the 34 inch (865 mm) high railing is provided is an alternative design, permitting individuals using wheelchairs...
-
3306.2 Walkways
Walkways shall be accessible in accordance with Chapter 11A or 11B as applicable, and shall be designed to support all imposed loads, and the design live load shall be not less than 150...
-
3306.2 Walkways
Walkways shall be accessible in accordance with Chapter 11A or 11B as applicable, and shall be designed to support all imposed loads, and the design live load shall be not less than 150...
- Cybex Total Access Row/Rear Delt Exercise Machine
-
Car Controls
...are the highest floor control buttons in the elevator(s) mounted within 54" of the floor, with associated raised letters and Braille characters?...
-
5c.
Are the highest floor control buttons in the elevator cab mounted no more than 54 inches above the floor for a side reach or 48 inches for forward reach? Yes _____ No _____...
-
1015.2 Where required
along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically to the floor...
-
Components (M303.4)
M303.4.1 would require the height of the breast platform to be 30 inches (760 mm) high minimum and 42 inches (1065 mm) high maximum above the floor when mammography equipment is used by...
-
4.34.6.5(1)
(1) The sink and surrounding counter shall be mounted at a maximum height of 34 in (865 mm) above the floor, measured from the floor to the top of the counter surface, or shall be adjustable...
-
11B-217.2 Wheelchair accessible telephones
TABLE 11B-217.2 WHEELCHAIR ACCESSIBLE TELEPHONES NUMBER OF TELEPHONES PROVIDED ON A FLOOR, LEVEL, OR EXTERIOR SITE MINIMUM NUMBER OF REQUIRED WHEELCHAIR...
-
11B-217.2 Wheelchair accessible telephones
TABLE 11B-217.2 WHEELCHAIR ACCESSIBLE TELEPHONES Number Of Telephones Provided On A Floor, Level, Or Exterior Site Minimum Number Of Required Wheelchair Accessible Telephones...
-
Employee Work Areas: ADA Standard Section 215.3
Section 215.3 covers scoping requirements in the current ADA Standards for fire alarm systems in employee work areas.
-
General: ADA Standard Section 243.1
Section 243.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for shooting facilities and firing positions.
-
[ADA Title III §36.104] 2010 Standards
[ADA Title III §36.104] 2010 Standards means the 2010 ADA Standards for Accessible Design, which consist of the 2004 ADAAG and the requirements contained in subpart D of this part....
-
SELF-SERVICE STORAGE
[DSA-AC] Building or facility designed and used for the purpose of renting or leasing individual storage spaces to customers for the purpose of storing and removing personal property on...
-
[ADA Title III §36.104] 2010 Standards
[ADA Title III §36.104] 2010 Standards means the 2010 ADA Standards for Accessible Design, which consist of the 2004 ADAAG and the requirements contained in subpart D of this part....
-
SELF-SERVICE STORAGE
[DSA-AC] Building or facility designed and used for the purpose of renting or leasing individual storage spaces to customers for the purpose of storing and removing personal property on...
-
306.2.1 General
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....
-
306.2.1 General
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....
-
306.2.1 General
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....
-
4.23.9* Medicine Cabinets
If medicine cabinets are provided, at least one shall be located with a usable shelf no higher than 44 in (1120 mm) above the floor space. The floor space shall comply with 4.2.4....