The space shall be 36 inches (914 mm) wide minimum and shall extend forward 48 inches (1219 mm) minimum from a line located 12 inches (305 mm) behind the rear edge of the seat....
Search Results "Drinking Fountain Spout Location"
-
11B-1009.2.3 Clear deck space
-
11B-809.9.1 Clear floor space
floor spaces 30 inches (762 mm) by 48 inches (1219 mm), with centerlines aligned with the centerline of the work surface, appliance, sink or fixture, shall be provided in the following locations...
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30 inches...
-
11B-703.7.2.6.1 Men’s toilet and bathing facilities
An equilateral triangle, ¼ inch (6.4 mm) thick with edges 12 inches (305 mm) long and a vertex pointing upward, shall be located at entrances to men’s toilet and bathing facilities....
-
1009.2.3 Clear Deck Space
The space shall be 36 inches (915 mm) wide minimum and shall extend forward 48 inches (1220 mm) minimum from a line located 12 inches (305 mm) behind the rear edge of the seat....
-
228.2 Mail Boxes
Where mail boxes are provided in an interior location, at least 5 percent, but no fewer than one, of each type shall comply with 309....
-
Section 35.151(g)(2)
In the NPRM, the Department proposed Sec. 35.151(g)(2) which prohibits wheelchair spaces and companion seating locations from being “located on, (or obstructed by) temporary platforms or...
-
Contrast
The proposed rule specified that detectable warnings in interior locations differ from adjoining walking surfaces in resiliency or sound-on-cane contact (705.2.3)....
-
Two-Way Communication
Comments recommended that the guidelines address emergency communication systems located in a closed compartment and apply the specifications for operable parts in section 309 to compartment...
-
Benches
If the bench is not located next to a wall, the bench must have back support that is 42 inches minimum in length and extends from a point 2 inches maximum above the seat to a point 18 inches...
-
F240.1.1 Additions
When the second phase is completed, at least 10 elevated play components must be located on an accessible route, and at least 7 ground level play components, including 4 different types,...
-
Data Analysis
For example, the area measurement depends on two variables that cannot be analyzed separately: the amount of space occupied by the physical dimensions of the WMD user and the actual location...
-
F) Library Services
may have a facility that is difficult to make accessible or lack the resources to make essential physical changes may choose to offer the programs and services in an alternate accessible location...
-
5.1 Public Notification of Availability
This notification should be of the same order of visibility and location as information regarding other attributes of a performance ("Dolby Sound", etc.)....
-
1.1.14 Flatness of ramp cross slope
In addition to the measurement locations in 1.1.14, if a portion of the ramp appears to be steeper than 1:48 (approximately 2%) measure at that location as well....
-
11B-406.5.10 Diagonal curb ramps
Diagonal curb ramps with flared sides shall have a segment of curb 24 inches (610 mm) long minimum located on each side of the curb ramp and within the marked crossing....
-
240.1.1 Additions
When the second phase is completed, at least 10 elevated play components must be located on an accessible route, and at least 7 ground level play components, including 4 different types,...
-
11B-603.6 Guest room toilet and bathing rooms
facilities, toilet and bathing rooms within guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall provide all toilet and bathing fixtures in a location...
-
1009.9 Signage
Additionally, visual characters, raised character and braille signage complying with Chapter 11A, Section 1143A and Chapter 11B, Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5 shall be located...
-
Accessible Routes: ADA Standard Section 1007.2
Accessible routes located on playing surfaces of miniature golf holes shall be permitted to use the exceptions in 1007.2. EXCEPTIONS: 1....
-
11B-213.3.6 Bathing facilities
compartments shall be permitted in transient lodging guest rooms, multi-bedroom housing units in undergraduate student housing and residential dwelling units; and shall not be permitted at other locations...
-
11B-802.1.3 Depth
A single wheelchair location space with side entry must functionally be usable as if it were within an alcove, requiring the user to maneuver back and forth to get into position, and thus...
-
11B-220.2 Point-of-sale devices
Where point-of-sale devices are provided, all devices at each location shall comply with Sections 11B-707.3, 11B-707.7.2, and 11B-707.9....
-
11B-220.2 Point-of-sale devices
Where point-of-sale devices are provided, all devices at each location shall comply with Sections 11B-707.3, 11B-707.7.2, and 11B-707.9....