Note: In determining equivalent facilitation, consideration shall be given to means that provide for the maximum independence of persons with disabilities while presenting the least risk...
Search Results "Maximum Extent Practicable"
-
EQUIVALENT FACILITATION
-
Top Landings
The proposed rule specified that side flares of 1:12 maximum must be provided when space at the top of curb ramps is less than 48 inches long. This specification has been removed....
-
214 and 611 Washing Machines and Clothes Dryers
An exception will permit the maximum height for the tops of these machines to be 2 inches higher than the general requirement for maximum high reach over an obstruction....
-
Elevated Accessible Routes
inch (915 mm) clear width 32-inch (815 mm) narrowed width permitted for 24-inch (610 mm) length to accommodate features in the composite structure 12-inch (305 mm) rise maximum...
-
Play Tables
17 inches (430 mm) deep minimum Play tables designed primarily for children under 5 years old may provide a parallel approach instead of knee clearance if the rim is a maximum...
-
405.2 Slope
Table 405.2 Maximum Ramp Slope and Rise for Existing Sites, Buildings, and Facilities Slope1 Maximum Rise Steeper than 1:10 but not steeper than 1:8 3...
-
11B-604 Water closets and toilet compartments
INTERPRETATION Showers are fixtures including a 30 inch x 60 inch clear receptor with a minimum/maximum slope of ¼ inch per foot to a drain (refer to CPC Section 408.5 and CBC Section...
-
405.2 Slope
Table 405.2 Maximum Ramp Slope and Rise for Existing Sites, Buildings, and Facilities Slope¹ Maximum Rise Steeper than 1:10 but not...
-
711.3.1 Through penetrations
space between the penetrating item and the fire-resistance- rated wall shall be permitted to be protected as follows: In concrete or masonry walls where the penetrating item is a maximum...
-
405.2 Slope
Table 405.2 Maximum Ramp Slope and Rise for Existing Sites, Buildings, and Facilities Slope1 Maximum Rise Steeper than 1:10 but not...
-
608.6 Shower Spray Unit and Water
Shower spray units shall deliver water that is 120°F (49°C) maximum....
-
Gratings [4.5.4]
ADAAG requires a maximum opening dimension of ½ inch in one direction and that elongated openings be placed so that the long dimension is perpendicular to the dominant direction of travel...
-
608.6 Shower Spray Unit and Water
Shower spray units shall deliver water that is 120°F (49°C) maximum....
-
11B-608.5.2 Standard roll-in type shower compartments
compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm) minimum and 27 inches (686 mm) maximum...
- Hager Companies 5400 Series - Standard Duty Surface Door Closer
- Pressalit Care PLUS Support Arm Height Adjustable Swing Grab Bar
- Mockett TLKNB27 Original Kyros Leg 5" Base
- Pressalit Care PLUS Support Arm Height and Sideways Adjustable Swing Grab Bar
- Pressalit Care VALUE Support Arm Height Adjustable
- Bobrick Automatic Foam Dispenser B-8263
- Bobrick Automatic Liquid Soap Dispenser B-826
- Guldmann GH1 Q Lifting Module
-
11B-1003.3.2 Boarding pier clearances
Every 10 feet (3048 mm) maximum of linear pier edge shall contain at least one continuous clear opening 60 inches (1524 mm) wide minimum....
-
232.2 General Holding Cells and General Housing Cells
EXCEPTION: Alterations to cells shall not be required to comply except to the extent determined by the Department in accordance with the variance procedures contained in Chapter 68, Texas...