Where a forward reach is unobstructed, the high forward reach shall be 1220 mm (4.0 ft) maximum and the low forward reach shall be 380 mm (1.25 ft) minimum above the finish surface....
Search Results "Maximum Extent Practicable"
-
R406.2 Unobstructed Forward Reach
-
Check-Out Areas [8.3]
Check-Out Areas [8.3] Check-out counters at accessible lanes are held to a maximum surface height of 36 inches....
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
7.2 SERVICE COUNTERS
exceeding 36 in (915 mm) in height are provided for standing sales or distribution of goods to the public, an auxiliary counter or a portion of the main counter shall be provided with a maximum...
-
Public Sector (Government) Facilities
subject to title II of the ADA except those with no more than two stories where the inaccessible story above (or below) the entry level has no public use space and an occupant load of five maximum...
-
4. Identification and Maintenance
As a practical matter, these same commenters noted that for users with visual impairments, receiving guidance from airline personnel to an accessible kiosk made more sense than affixing...
- Delta Electronic Lav with Mixer NS DEMD-311LF
- Pressalit Care VALUE Support Arm Fixed Height Swing Grab Bar
- Delta Electronic Lavatory NS DEMD-301LF
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
1008.4.4 Entry Points and Seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
Gas Pump Force
Gas pump manufacturers indicated that the safety requirements for the operation of gas pump nozzles effectively preclude a maximum operating force of 5 pounds. Response....
-
§382.133(h)(2)
manufacturer's estimate of the hours of battery life while the device is in use and the information provided in the physician's statement, to power the device for not less than 150% of the expected maximum...
-
705.1.2 Dome Spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 1.6 inches (41 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
605.2 Height and Depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (430 mm) maximum above the finish floor or ground....
-
705.1.2 Dome Spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 1.6 inches (41 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
608.3.3 Alternate Roll-In Type Shower Compartments
Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls....
-
R402.4 Reduced Vertical Clearance
The leading edge of the guardrail or barrier shall be located 685 mm (2.25 ft) maximum above the finish surface....
-
1008.4.4 Entry Points and Seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
407.8.3 Forward Reach
Where a forward reach allows a reach over a portion of the ICT, the height of that portion of the ICT shall be 34 inches (865 mm) maximum....
-
11B-1009.4.3 Wall depth and length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (406 mm) maximum....
-
407.12.3 Forward Reach
Where a forward reach allows a reach over a portion of the ICT, the height of that portion of the ICT shall be 34 inches (865 mm) maximum....
-
11B-608.3.3 Alternate roll-in type shower compartments
Grab bars shall be installed 6 inches (152 mm) maximum from adjacent walls....