These guidelines are to be applied during the design, construction, and alteration of such buildings and facilities to the extent required by regulations issued by Federal agencies, including...
Search Results "Maximum Extent Practicable"
-
1. PURPOSE.
-
The Participants
To the extent possible, each group was equally represented by age: youth (age 9- 18 years) and adults (18 years and above). The age of the participants ranged from 9 to 65 years....
-
1.6 Vehicular Way Exception
accessible spaces on a site is a vehicular way not providing pedestrian access, an accessible route connecting them is not required.3, 4 The Section 11B-203 exceptions also apply to the extent...
-
3.1 Disproportionate Costs for Small Projects
When the cost of full compliance with Section 11B-202.4 would exceed 20 percent, compliance shall be provided to the greatest extent possible without exceeding 20 percent....
-
[2010 ADA Standards] 105.1 General
The standards listed in 105.2 are incorporated by reference in this document and are part of the requirements to the prescribed extent of each such reference....
-
Section 610 Review
consider five factors: (1) The continued need for the rule; (2) the nature of complaints or comments received concerning the rule from the public; (3) the complexity of the rule; (4) the extent...
-
Exception 8
When the cost of full compliance with Section 11B-202.4 would exceed 20 percent, compliance shall be provided to the greatest extent possible without exceeding 20 percent....
-
Section 610 Review
consider five factors: (1) The continued need for the rule; (2) the nature of complaints or comments received concerning the rule from the public; (3) the complexity of the rule; (4) the extent...
-
T302 Walking Surfaces
The technical requirements for walking surfaces include provisions on slip resistance, the maximum size of surface openings, and the maximum height of vertical surface discontinuities (i.e...
-
Knee and Toe Clearance (M303.2.4)
M303.2.4 would require the depth of wheelchair spaces to include knee and toe clearance of 17 inches minimum and 25 inches maximum....
-
603.4 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor. [ECTCR UFAS 4.25.3, Fig. 38]...
-
11B-703.2.8 Line spacing
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height. [S.H. ...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
602.5 Spout Location
The spout shall be located 15 inches (380 mm) minimum from the vertical support and 5 inches (125 mm) maximum from the front edge of the unit, including bumpers....
-
602.5 Spout Location
The spout shall be located 15 inches (380 mm) minimum from the vertical support and 5 inches (125 mm) maximum from the front edge of the unit, including bumpers....
-
1009.6.1 Pool Stairs
EXCEPTION: Pool step riser heights shall not be required to be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum provided that riser heights are uniform....
-
11B-1009.6.1 Pool stairs
Exception: Pool step riser heights shall not be required to be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum provided that riser heights are uniform....
-
B1. Slope
Is a relatively level (1:50 or 2% maximum slope in all directions) access aisle provided adjacent and parallel to the side of the vehicle pull-up area?...
-
Clear Width [4.8.3]
A maximum clear width is not specified....
-
11B-1009.6.1 Pool stairs
Exception: Pool step riser heights shall not be required to be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum provided that riser heights are uniform....
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
Currently, the DCFC time limit is 30 minutes maximum. New larger battery capacity will take longer to get 80% charge – i.e. Chevy Bolt EV, Tesla Model 3, 2018 Nissan LEAF, etc. Can we reconsider the time limit?
RESPONSE: The 30 minute time limit applies to drive-up EVCS of any type. This design option allows brief charging and queuing for charging service, and does not consider that...
-
Outdoor Developed Areas: ADA Standard Section 9.
Review the updated information on the revisions to the ADA Standards regarding outdoor developed areas.
-
502.3.3 Values (Section-by-Section Analysis)
However, existing industry practice in response to existing standards (i.e., 508 Standards § 1194.21(d)) is to permit values to be set programmatically....