Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
Search Results "Maximum Extent Practicable"
Commonly Searched Documents
-
11B-307.4.1 Guy braces
-
1009.4.3 Wall Depth and Length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (405 mm) maximum....
-
407.2.1.1 Height
EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of the highest operable...
-
Seat Height
Seat Height The lift must be designed so that the seat will make a stop between a minimum of 16 inches and maximum of 19 inches (measured from the deck to the top of the seat surface,...
-
604.9.5 Flush Controls
Hand operated flush controls shall comply with 309.2 and 309.4 and shall be installed 36 inches (915 mm) maximum above the finish floor....
-
604.9.5 Flush Controls
Hand operated flush controls shall comply with 309.2 and 309.4 and shall be installed 36 inches (915 mm) maximum above the finish floor....
-
407.2.1.1 Height
EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of the highest operable...
-
4.7.2 SLOPE
Maximum slopes of adjoining gutters, road surface immediately adjacent to the curb ramp, or accessible route shall not exceed 1.20....
-
4.34.6.4(1)
(1) The counter shall be mounted at a maximum height of 34 in (865 mm) above the floor, measured from the floor to the top of the counter surface, or shall be adjustable or replaceable as...
-
M302.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
M301.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
11B-246.2 Camping facilities
provided, at least two campsites and one additional campsite for each 100 campsites or fraction thereof, shall be accessed by and connected to sanitary facilities by travel routes with a maximum...
-
11B-605.2 Height and depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground....
-
11B-246.2 Camping facilities
provided, at least two campsites and one additional campsite for each 100 campsites or fraction thereof, shall be accessed by and connected to sanitary facilities by travel routes with a maximum...
-
11B-503.3.3 Marking
The area within the borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface....
-
Accessible Means for Gathering Feedback
Accessible Means for Gathering Feedback If businesses want to gain input from people with disabilities, their research and consultation practices should be accessible to these customers...
-
ENSURING POLICIES AND PROCEDURES DO NOT DISCRIMINATE AGAINST PEOPLE WITH DISABILITIES
ENSURING POLICIES AND PROCEDURES DO NOT DISCRIMINATE AGAINST PEOPLE WITH DISABILITIES Public entities must ensure that they do not have policies, procedures, or practices in place that...
-
ADA Coordinator, Grievance Procedure, Self-Evaluations, and Transition Plans
The 1991 ADA regulation required all public entities, regardless of size, to evaluate all of their services, policies, and practices and to modify any that did not meet ADA requirements....
- Midmark 641 Barrier-Free® Power Procedures Chair
- Hadrian Inc. Gladiator Athletic Lockers
-
502.3.3 Values (Section-by-Section Analysis)
However, existing industry practice in response to existing standards (i.e., 508 Standards § 1194.21(d)) is to permit values to be set programmatically....
-
E204.1 General (Section-by-Section Analysis)
This proposed section is consistent with current agency practice....
-
I. Other Resources
Other issues are addressed in Chapter 7 of the “ADA Best Practices Tool Kit for State and Local Governments,” “The ADA Guide for State and Local Governments: Making Emergency Preparedness...
-
Who Will Provide the Assistance?
A practical plan should identify at least two, ideally more, people who are willing and able to provide assistance....