Element Identified in Attachments X, X, and X to the Consent Decree: Description of Element: Location of Element: ____________________ Date _________________________________...
Search Results "Wet Location"
-
Attachment B
-
Three Additional Features for Van-Accessible Parking Spaces
symbol of accessibility mounted high enough so the sign can be seen when a vehicle is parked in the space 96" min. width access aisle, level (max. slope 1:50 in all directions), located...
-
1009.2.1 Elevators required
throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required on floors provided with a horizontal exit and located...
-
1009.4.2 Area of refuge
Areas of refuge are not required at elevators not required to be located in a shaft in accordance with Section 712....
-
11B-809.10.7.1 Floor space
Exception: The 48-inch (1219 mm) minimum clear width may be reduced to 36 inches (914 mm) minimum for lavatories, cabinets, wing walls, or privacy walls located immediately adjacent to a...
-
11B-411.2.1.6 Identification of floors served
In buildings with two or more elevator banks, each serving a different group of specific floors, hall call consoles located on floors with a building entry, including parking and transfer...
-
1009.2.1 Elevators required
throughout with an automatic sprinkler system installed in accordance with Section 903.3.1 or 903.3.1.2, the elevator shall not be required on floors provided with a horizontal exit and located...
-
Re: Lavatories Adjacent to Partitions
Lavatories, when located adjacent to a side wall or partition, shall be a minimum of 18 inches (457 mm) to the centerline of the fixture....
-
Transfer Devices for Use with Amusement Rides: ADA Standard Section 1002.6
Where possible, designers are encouraged to locate the transfer device seat no higher than 17 to 19 inches 430 to 485 mm) above the load and unload surface....
-
Outdoor Developed Areas: ADA Standard Section 9.
Review the updated information on the revisions to the ADA Standards regarding outdoor developed areas.
-
1010.2.13.1 Delayed egress locking system
A sign shall be provided on the door and shall be located above and within 12 inches (305 mm) of the door exit hardware: 6.3....
-
11B-809.10.7.3 Reinforcement for grab bars
Where the water closet is located adjacent to lavatories, cabinets, wing walls, or privacy walls the grab bar reinforcement shall be 36 inches (914 mm) in length....
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
The following may only be used for determining required access to multifamily dwelling units, in a single building with one common (lobby) entrance, located on a site with difficult terrain...
-
11B-1002.6 Transfer devices for use with amusement rides
Where possible, designers are encouraged to locate the transfer device seat no higher than 17 to 19 inches (430 to 485 mm) above the load and unload surface....
-
1013.4 Raised character and braille exit signs
[HCD 1-AC] Tactile exit signs shall be required at the following locations: 1....
-
1010.2.12.1 Delayed egress locking system
A sign shall be provided on the door and shall be located above and within 12 inches (305 mm) of the door exit hardware: 6.3....
-
11B-1002.6 Transfer devices for use with amusement rides
Where possible, designers are encouraged to locate the transfer device seat no higher than 17 to 19 inches (430 to 485 mm) above the load and unload surface....
-
11B-809.10.7.3 Reinforcement for grab bars
Where the water closet is located adjacent to lavatories, cabinets, wing walls, or privacy walls the grab bar reinforcement shall be 36 inches (914 mm) in length....
-
11B-232.1 General
providing the required mobility features in substitute cells (cells other than those where alterations are originally planned), provided that each substitute cell— i) Is located...
-
11B-232.1 General
providing the required mobility features in substitute cells (cells other than those where alterations are originally planned), provided that each substitute cell— i) Is located...
-
1007.2.1 Elevators required
throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required on floors provided with a horizontal exit and located...
-
Overlapping Clear Floor Space
Comments recommended that this provision be revised to recognize that a seat may not always be located in a roll-in shower. Response....
-
11B-809.1 General
When located within public housing facilities, residential dwelling units shall comply with Section 11B-809....