are provided in the bathroom: • Comparable vanity counter top space (section 806); • Standard roll-in type shower with folding seat (section 608.2.2); • Recessed roll-in shower location...
Search Results "Wet Location"
-
Plan 2A: 13-Foot Wide Accessible Guest Room
-
Plan 2B: 13-Foot Wide Accessible Guest Room
wide (section 608.2.3); • Alternate roll-in shower has a 36-inch wide entry at one end of the long side of the compartment (section 608.2.3); • Recessed alternate roll-in shower location...
-
Issue 10: Braille (right side up?)
Where the APS device includes the street name in Braille, care must be taken to install the signs in the correct location and orientation. ...
-
TICKETING
the purchase of other tickets; Accessible seating must be identified to the same level of specificity as other seats on maps, seating charts, and brochures, and, if asked, the location...
-
233.3.2.1 Facilities Other Than Those Containing Emergency Transportable Housing Units, F233.3.2.1 Facilities Other Than Those Containing Emergency Transportable Housing Units, F233.4.2.1 Facilities Other Than Those Containing Emergency Transportable Housing Units
units, the requirements of 233.3.2.1 shall apply to the total number of residential dwelling units that are constructed under a single contract, or are developed as a whole, whether or not located...
-
11B-604.5 Grab bars
installed in a toilet room for a single occupant accessed only through a private office and not for common use or public use provided that reinforcement has been installed in walls and located...
-
11B-410.1 General
Accessibility scoping requirements for elevators and lifts are located in Sections 11B-206.6 and 11B-206.7; technical requirements are located in Sections 11B-407, 11B-408, 11B-409 and 11B...
-
11B-410.1 General
Accessibility scoping requirements for elevators and lifts are located in Sections 11B-206.6 and 11B-206.7; technical requirements are located in Sections 11B-407, 11B-408, 11B-409 and 11B...
-
11B-604.5 Grab bars
installed in a toilet room for a single occupant accessed only through a private office and not for common use or public use provided that reinforcement has been installed in walls and located...
- Kohler® Mazz Single-Handle Pull-Down Sprayer Kitchen Faucet in Vibrant Stainless
- Symmons HC3/HC4 Folding Padded Shower Seat & Grab Bar
- Outdoor Extreme Mobility Beach Cruiser Powered Wheelchair
- Corbin Russwin Inc. HPSK Push Pull Paddle Trim
-
Toilet Compartment Access
Doors shall be located in the front partition or in the side wall or partition farthest from the water closet....
-
Ticket Prices and Dispersal of Wheelchair Spaces
the total number of tickets at that price level to the total number of tickets in the assembly area) shall be offered for purchase, at that price level, in a nearby or similar accessible location...
-
BACKGROUND
For the March 2016 Primary Election, the Board used 50 temporary and permanent Early Voting polling place locations at remote locations....
-
9.b [§ 4.7.5]
Place the level in the same position and location as each of the arrows in the illustration to the left [below]....
-
F216.12 Amusement Rides
In addition, where accessible unload areas also serve as accessible load areas, signs indicating the location of the accessible load and unload areas shall be provided at entries to queues...
-
1.12 Future Construction Theaters
Those seating plans have been specifically approved by the United States as compliant with the wheelchair seating location requirements of both Standard 4.33.3 and §§ 221 and 802 of the...
-
11B-806.2.4 Toilet and bathing facilities
Toilet and bathing fixtures required to comply with Sections 11B-603 through 11B-610 shall be permitted to be located in more than one toilet or bathing area, provided that travel between...
-
11B-307.4 Vertical clearance
The leading edge of such guardrail or barrier shall be located 27 inches (686 mm) maximum above the finish floor or ground....
-
13 [§ 4.7.10]
13 [§ 4.7.10] A corner-type curb ramp is located at the center (or apex) of a corner and is often aligned to direct users into the middle of an intersection....
-
5.4.4.1 Transfer Support Distance from Transfer Surface Recommendation for Stretchers
5.4.4.1 Transfer Support Distance from Transfer Surface Recommendation for Stretchers The Committee recommends locating the transfer support along the long side of the of the transfer...