Section 227.3 covers scoping requirements in the current ADA Standards for counters.
Search Results "Shall"
-
Counters: ADA Standard Section 227.3
-
Toilet Compartments: ADA Standard Section 213.3.1
Section 213.3.1 covers scoping requirements in the current ADA Standards for toilet compartments.
-
11B-407.2.3.1 Floor designation
Floor designations shall be provided in both raised characters and braille. Raised characters shall be 2 inches (51 mm) high....
-
11B-407.2.3.1 Floor designation
Floor designations shall be provided in both raised characters and Braille. Raised characters shall be 2 inches (51 mm) high....
-
Sound Pressure Level: ADA Standard Section 706.4
Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB....
-
11B-706.4 Sound pressure level
Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB....
-
Vehicle Pull-Up Space: ADA Standard Section 503.2
Section 503.2 covers the current ADA Standards for vehicle pull-up space at passenger loading zones.
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
11B-206.4.4 Transportation facilities
In addition to the requirements of Sections 11B-206.4.2, 11B-206.4.3, and 11B-206.4.5 through 11B-206.4.9, transportation facilities shall provide entrances in accordance with Section 11B...
-
11B-405.4 Floor or ground surfaces
Floor or ground surfaces of ramp runs shall comply with Section 11B-302. Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
11B-231.4.2 Partitions
Where solid partitions or security glazing separate visitors from detainees at least one of each type of cubicle or counter partition shall comply with Section 11B-904.6....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
11B-217.4.5 Rest stops, emergency roadside stops, and service plazas
Where at least one public pay telephone is provided at a public rest stop, emergency roadside stop, or service plaza, at least one public TTY shall be provided....
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....
-
11B-706.4 Sound pressure level
Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB....
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....
-
11B-231.4.2 Partitions
Where solid partitions or security glazing separate visitors from detainees at least one of each type of cubicle or counter partition shall comply with Section 11B-904.6....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-217.4.5 Rest stops, emergency roadside stops, and service plazas
Where at least one public pay telephone is provided at a public rest stop, emergency roadside stop, or service plaza, at least one public TTY shall be provided....
-
Rest Stops, Emergency Roadside Stops, and Service Plazas: ADA Standard Section 217.4.5
Section 217.4.5 covers scoping requirements in the current ADA Standards for TTYs at rest stops, emergency roadside stops, and service plazas.
-
11B-106.3 Undefined terms
The meaning of terms not specifically listed in Section 11B-106.5, and not defined in Chapter 2, Section 202, or in referenced standards shall be as defined by collegiate dictionaries in...
-
11B-208.3.3 Private garages accessory to residential dwelling units
Private garages accessory to residential dwelling units shall comply with Section 11B-208.3....