Signs are required to indicate the availability of assistive listening systems, which are required in certain assembly areas (216.10)....
Search Results "Floor Destination Indicator"
-
Assistive Listening System Signage
-
Pushbutton-integrated APS
All include a pushbutton that is at least 50 mm (2 inches) in diameter, audible and vibrotactile WALK indications, a pushbutton locator tone, a tactile arrow, and automatic volume adjustment...
-
Location of Controls
Comments indicated that this specification was not consistent with a corresponding figure showing the location on the side closest to the shower opening. Response....
-
Tips for Assisting People Who Have Difficulty Speaking
Difficulty speaking does not indicate a lack of intelligence....
-
"Alerting to intruders." (Section-by-Section Analysis)
Commenters indicated that "alerting to intruders" has been misinterpreted by some individuals to apply to a special line of protection dogs that are trained to be aggressive. ...
-
Recognizing a TTY Call
(When a call is made through the TTY relay service, the service operator will indicate by voice that it is a TTY relay call.)...
-
Section 4.1.2, Accessible Sites and Exterior Facilities: New Construction (Section-By-Section Analysis and Response to Comments)
These spaces must have a sign indicating that they are van-accessible, but they are not to be reserved exclusively for van users....
-
2. The specific risk must be identified
For example: A physician's evaluation of an applicant for a heavy labor job that indicated the individual had a disc condition that might worsen in 8 or 10 years would not be sufficient...
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30 inches...
-
11B-809.10.8.1 Location
The top of the lavatory rim shall be 34 inches (864 mm) maximum above the finished floor....
-
11B-809.10.8.1 Location
The top of the lavatory rim shall be 34 inches (864 mm) maximum above the finished floor....
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30 inches...
-
Protrusions
Where a wheelchair space is located on a ride, nothing may protrude into the front of the wheelchair space 9 inches from the floor....
-
Gaps
Gaps Where wheelchair spaces are provided on amusement rides, the floors of rides must be coordinated with the floors of the load and unload areas so that when the ride is at the...
-
Do all state and local buildings need to be accessible (comply with the ADA Standards for Accessible Design?)
In a two story town hall built in 1968 that doesn’t have an elevator, staff on the second floor could meet with citizens on the first floor if meeting space is comparable to that on the...
-
M303.2.4.2 Knee Clearance
Knee clearance shall be provided at a depth of 11 inches (280 mm) minimum and 25 inches (635 mm) maximum at 9 inches (230 mm) above the floor and at a depth of 8 inches (205 mm) minimum...
-
11B-404.2.7 Door and gate hardware
Operable parts of such hardware shall be 34 inches (864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground....
-
11B-404.2.7 Door and gate hardware
Operable parts of such hardware shall be 34 inches (864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground....
-
Drinking Fountain Scoping for Exterior Sites
In the final rule, scoping has been clarified as applying to units provided at "exterior sites," in addition to those installed on floors....
-
Example: Historic House Museum
The town develops plans to alter the facility to provide physical access to the first floor....
- Designing with People
-
1(3)(a)(i)
(i) Where a building elevator is provided only as a means of creating an accessible route to dwelling units on a ground floor, the building is not considered an elevator building for purposes...
-
K4
If built-in food, drink, condiment, and tableware dispensers are provided, are dispensers and operating controls mounted no higher than 54 inches above the floor if clear floor space is...
-
1(3)(a)
(a) There is an elevator connecting the parking area with the dwelling units on a ground floor....