compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum above the shower floor...
Search Results "Floor Destination Indicator"
-
11B-608.5.1 Transfer type shower compartments
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
11B-902.4 Dining surfaces and work surfaces for children’s use
Exception: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with Section 11B-902.4 where a clear floor or ground...
-
11B-902.4 Dining surfaces and work surfaces for children’s use
Exception: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with Section 11B-902.4 where a clear floor or ground...
-
11B-608.5.1 Transfer type shower compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum above the shower floor...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space....
-
11B-405.9.1 Reserved
[2010 ADAS] 405.9.1 Extended Floor or Ground Surface. ...
-
11B-405.9.1 Reserved.
[2010 ADA Standards] 405.9.1 Extended Floor or Ground Surface....
-
11B-202 Existing buildings and facilities
The language "primary accessible path of travel shall include" indicates that, in most projects, accessibility must be demonstrated and/or provided outside of the specific area of alteration...
-
1118B.4
One full unobstructed side of the clear floor or ground space for a wheelchair shall adjoin or overlap an accessible route or adjoin another wheelchair clear floor space....
-
217.4.2.1 Public Buildings
Where at least one public pay telephone is provided on a floor of a public building, at least one public TTY shall be provided on that floor....
-
217.4.2.2 Private Buildings
Where four or more public pay telephones are provided on a floor of a private building, at least one public TTY shall be provided on that floor....
-
Overhead Lifts
Overhead lifts and portable floor lifts are used in health care facilities, and the technical criteria should not be viewed as preferring portable floor lifts....
-
11B-407.2.1.5 Signals
Call buttons shall have visible signals to indicate when each call is registered and when each call is answered. Exceptions: 1. Reserved. 2. Reserved....
-
Documentation of Need for Accommodation
Such documentation might indicate, for example, that this person cannot lift more than 15 pounds without assistance....
-
Section 4.1.2, Accessible Sites and Exterior Facilities: New Construction (Preamble, Section-by-Section Analysis)
These spaces must have a sign indicating that they are van-accessible, but they are not to be reserved exclusively for van users....
-
4.30.7(3)
In addition, if a facility has a public text telephone, directional signage indicating the location of the nearest text telephone shall be placed adjacent to all banks of telephones which...
-
APPENDIX
Sections of the guidelines for which additional material appears in this appendix have been indicated by an asterisk....
-
Two-Way Communication Systems [§230 and §708]
Lighted signals should have labels to indicate their meaning. If handsets are provided, cords must be at least 29” long....
-
11B-407.2.1.5 Signals
Call buttons shall have visible signals to indicate when each call is registered and when each call is answered. Exceptions: 1. Reserved. 2. Reserved. [2010 ADAS] 2....
-
11B-407.2.1.5 Signals
Call buttons shall have visible signals to indicate when each call is registered and when each call is answered. Exceptions: Reserved. Reserved. [2010 ADA Standards] 2....
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...