EXCEPTION: Openings for wheel flanges shall be permitted to be 2½ inches (64 mm) maximum. Figure 810.10 (Exception) Track Crossings...
Search Results "Maximum Reach Depth"
-
810.10 Track Crossings
-
4.3.5 Transfer Height
Tent platform surfaces that are not the same elevation as the ORAR shall be between 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the floor or ground surface adjacent to...
-
R305.1.2 Dome Spacing
The truncated domes shall have a center-to-center spacing of 41 mm (1.6 in) minimum and 61 mm (2.4 in) maximum, and a base-to-base spacing of 17 mm (0.65 in) minimum, measured between the...
-
4.3.5 Transfer Height
Tent platform surfaces that are not the same elevation as the ORAR shall be between 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the floor or ground surface adjacent to...
-
7.3 CHECK-OUT AISLES
Clear aisle width shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 36 in (915 mm) above the floor....
-
11B-703.5.8 Character spacing
Spacing between individual characters shall be 10 percent minimum and 35 percent maximum of character height....
-
11B-1009.6.1 Pool stairs
Exception: Pool step riser heights shall not be required to be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum provided that riser heights are uniform....
-
T302 Walking Surfaces
The technical requirements for walking surfaces include provisions on slip resistance, the maximum size of surface openings, and the maximum height of vertical surface discontinuities (i.e...
- Grainger Soap Dispenser, 800mL, Ceramic White
- Gamco Recessed Coverall Toilet Seat-Cover Dispenser - TSC-8
-
11B-703.2.8 Line spacing
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height. [S.H. ...
-
602.5 Spout Location
The spout shall be located 15 inches (380 mm) minimum from the vertical support and 5 inches (125 mm) maximum from the front edge of the unit, including bumpers....
-
602.5 Spout Location
The spout shall be located 15 inches (380 mm) minimum from the vertical support and 5 inches (125 mm) maximum from the front edge of the unit, including bumpers....
-
1009.6.1 Pool Stairs
EXCEPTION: Pool step riser heights shall not be required to be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum provided that riser heights are uniform....
-
11B-1009.6.1 Pool stairs
Exception: Pool step riser heights shall not be required to be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum provided that riser heights are uniform....
-
§ 36.405(a)
the National Register of Historic Places under the National Historic Preservation Act (16 U.S.C. 470 et seq) or are designated as historic under State or local law, shall comply to the maximum...
-
B1. Slope
Is a relatively level (1:50 or 2% maximum slope in all directions) access aisle provided adjacent and parallel to the side of the vehicle pull-up area?...
-
Clear Width [4.8.3]
A maximum clear width is not specified....
-
11B-1009.6.1 Pool stairs
Exception: Pool step riser heights shall not be required to be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum provided that riser heights are uniform....
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
- GE® 30" Drop-In Electric Range JDS28DFWW
- VE CONNECT Smart Vending Machine
- Kawneer North America 2000T Terrace Doors
-
Currently, the DCFC time limit is 30 minutes maximum. New larger battery capacity will take longer to get 80% charge – i.e. Chevy Bolt EV, Tesla Model 3, 2018 Nissan LEAF, etc. Can we reconsider the time limit?
RESPONSE: The 30 minute time limit applies to drive-up EVCS of any type. This design option allows brief charging and queuing for charging service, and does not consider that...