Recommendation of a 19" Lower Adjsutable Height as the Minimum Accessibility Standrds (Joint Report)...
Search Results "Minimum Dimension"
Commonly Searched Documents
-
Recommendation of a 19" Lower Adjsutable Height as the Minimum Accessibility Standrds (Joint Report)
-
IMPLICATION OF A 19-INCH MINIMUM STANDARD FOR THE HIGHEST POINT IN THE LOWEST ADJUSTABLE POSITION
IMPLICATION OF A 19-INCH MINIMUM STANDARD FOR THE HIGHEST POINT IN THE LOWEST ADJUSTABLE POSITION This minority report presents the factors that support a minimum standard of 19 inches...
-
C101.3 Conventional Industry Tolerances
Dimensions are subject to conventional industry tolerances except where dimensions are stated as a range with specific minimum or maximum end points....
-
E101.3 Conventional Industry Tolerances
Dimensions are subject to conventional industry tolerances except where dimensions are stated as a range with specific minimum or maximum end points....
-
Conventions [§104]
Conventions [§104] Most dimensions in the ADA Standards are specified as a minimum, maximum, or as a range. In a few areas, absolute dimensions are specified....
-
11B-703.6.1 Pictogram field
Pictograms shall have a field height of 6 inches (152 mm) minimum. Characters and Braille shall not be located in the pictogram field. Advisory 11B-703.6.1 Pictogram field....
-
F233.3.1 Minimum Number: New Construction
Newly constructed facilities with residential dwelling units shall comply with F233.3.1.
-
F233.4.1 Minimum Number: New Construction
Newly constructed facilities with residential dwelling units shall comply with F233.4.1. EXCEPTION: Where facilities contain 15 or fewer residential dwelling units, the...
-
233.3.1 Minimum Number: New Construction
Newly constructed facilities with residential dwelling units shall comply with 233.3.1. EXCEPTION: Where facilities contain 15 or fewer residential dwelling units, the...
-
11B-240.2.1.1 Minimum number and types
Where ground level play components are provided, at least one of each type shall be on an accessible route and shall comply with Section 11B-1008.4.
-
11B-240.2.1.1 Minimum number and types
Where ground level play components are provided, at least one of each type shall be on an accessible route and shall comply with Section 11B-1008.4.
-
11B-240.2.1.1 Minimum number and types
Where ground level play components are provided, at least one of each type shall be on an accessible route and shall comply with Section 11B-1008.4.
-
Calculation of Percentages
Some provisions in the ADA Standards specify a minimum number of elements or spaces as a minimum percentage or proportion....
-
Caution regarding minimum Aisle Widths for aisles that serve "elements on both sides"
As a heads up, care should be taken in applying the technical aspects of 11B-403.5.1, Exception 4 re: minimum aisle width in California....
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
Location: ADA Standard Section 604.2
Section 604.2 covers the current ADA Standards for the mounting location of water closets.
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
5.8.2 Knee and Toe Clearance Recommendations under Breast Platform Recommendations
Table 5.8.2(a) Recommended Dimensions for Knee and Toe Clearances Proposed Dimensions Based on 2010 Standards Dimensions Recommended by Wheeled Mobility Anthropometry...
-
Section 36.303(g)(4) Minimum Requirements for Audio Description Devices
In the NPRM, the Department proposed at § 36.303(g)(3)(ii)(A) that movie theaters maintain one audio description device per auditorium, with a minimum of two devices per movie theater....
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning...