Amendments Act's purpose of reinstating a broad scope of protection under the ADA, the definition of “disability” in this part shall be construed broadly in favor of expansive coverage to the maximum...
Search Results "Maximum Dimension"
-
§1630.1(c)(4) Broad coverage
-
§ 37.43(a)(2)
alteration that affects or could affect the usability of or access to an area of a facility containing a primary function, the entity shall make the alteration in such a manner that, to the maximum...
-
11B-810.2.3 Connection
alighting areas shall provide a detectable transition between the boarding/alighting area and the roadway; the detectable transition shall consist of a curb with the face sloped at 35 degrees maximum...
-
11B-1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be permitted to be reduced to 32 inches (813 mm) minimum for a distance of 24 inches (610 mm) maximum provided...
-
11B-1007.3.2 Golf club reach range area
All areas within holes where golf balls rest shall be within 36 inches (914 mm) maximum of a clear floor or ground space 36 inches (914 mm) wide minimum and 48 inches (1219 mm) long minimum...
-
11B-1007.3.2 Golf club reach range area
All areas within holes where golf balls rest shall be within 36 inches (914 mm) maximum of a clear floor or ground space 36 inches (914 mm) wide minimum and 48 inches (1219 mm) long minimum...
-
11B-810.2.3 Connection
alighting areas shall provide a detectable transition between the boarding/alighting area and the roadway; the detectable transition shall consist of a curb with the face sloped at 35 degrees maximum...
-
11B-705.1.2.3 Islands or cut-through medians
warnings at pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2 inches (51 mm) maximum...
-
404.2.11 Vision Lights
adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1090 mm) maximum...
-
303.3 Beveled
Changes in level between 1/4 inch (6.4 mm) high minimum and 1/2 inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2. Advisory 303.3 Beveled....
-
1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be permitted to be reduced to 32 inches (815 mm) minimum for a distance of 24 inches (610 mm) maximum provided...
-
1007.3.2 Golf Club Reach Range Area
All areas within holes where golf balls rest shall be within 36 inches (915 mm) maximum of a clear floor or ground space 36 inches (915 mm) wide minimum and 48 inches (1220 mm) long minimum...
-
405.9 Edge Protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (13 mm) maximum within 10 inches (255 mm) horizontally of the minimum landing area...
-
1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be permitted to be reduced to 32 inches (815 mm) minimum for a distance of 24 inches (610 mm) maximum provided...
-
410.6 Doors and Gates
EXCEPTION: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self-closing manual doors or gates....
- Increasing Opportunities for Access on the Appalachian Trail: A Design Guide
- Easterseals Blake Foundation
- Disability Services & Legal Center - Santa Rosa, Napa, Ukiah, CA
- Independent Living Resource Center, INC. - Santa Barbara, Atascadero, Santa Maria, Ventura, Concord, Antioch, Fairfield, CA
-
Running Slope [1017.7.1]
Table 2—Maximum Running Slope and Segment Length Running Slope of Trail Segment Maximum Length of Segment Steeper Than But Not Steeper Than ...
-
R402 Protruding Objects (Section-by-Section Analysis)
between posts and the clear distance between the posts is more than 305 millimeters (1 foot), the lowest edge of the object must be 685 millimeters (2.25 feet) minimum or 2 meters (6.7 feet) maximum...
-
Revised and New Standards for Buildings and Facilities
Newly designed and constructed places of lodging must comply with the new 2010 ADA Standards, and alterations must comply to the maximum extent feasible....
-
11B-604.8.1.2 Doors
Where located in the front partition, the door opening shall be 4 inches (102 mm) maximum from the side wall or partition farthest from the water closet....
- American Standard Colony PRO Two-Handle Kitchen Faucet with Low-Arc Swivel Spout 7074.500