technical requirements for dining surfaces in 902.3 of the Architectural Barriers Act Accessibility Guidelines, which requires the tops of dining surfaces to be 28 inches minimum and 34 inches maximum...
Search Results "Maximum Dimension"
-
1011.4 Picnic Tables
-
Escalators
The referenced ASME criteria require steps to be demarcated by yellow lines 2” wide maximum along the back and sides (§6.1.3.5.6) and specify at least 2, but no more than 4, flat steps at...
-
M101.3 Equivalent Facilitation
., use of a patient lift) are not permitted because they do not provide for independent access to and use of diagnostic equipment by patients with disabilities to the maximum extent possible...
-
1607A.8.2 Grab bars, shower seats and dressing room bench seats
room bench seat systems shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab bar or seat so as to produce the maximum...
-
11B-603.5 Accessories
All operable parts, including coin slots, shall be 40 inches (1016 mm) maximum above the finish floor....
-
11B-1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (864 mm) maximum above the ground or deck surface....
-
11B-407.2.1.4 Location
Responding cars are programmed for maximum efficiency by reducing the number of stops any passenger experiences. ◼...
-
11B-1008.2.4.2 Elevated
Exceptions: The clear width of accessible routes connecting elevated play components shall be permitted to be reduced to 32 inches (813 mm) minimum for a distance of 24 inches (610 mm) maximum...
-
11B-603.5 Accessories
All operable parts, including coin slots, shall be 40 inches (1016 mm) maximum above the finish floor....
-
11B-809.10.7.1 Floor space
width may be reduced to 36 inches (914 mm) minimum for lavatories, cabinets, wing walls, or privacy walls located immediately adjacent to a water closet which extend 24 inches (610 mm) maximum...
-
11B-1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (864 mm) maximum above the ground or deck surface....
-
405.9 Edge Protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (13 mm) maximum within 10 inches (255 mm) horizontally of the minimum landing area...
-
303.3 Beveled
Changes in level between ¼ inch (6.4 mm) high minimum and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2. Advisory 303.3 Beveled....
-
Categorization of wheelchair versus other power-driven mobility devices. (Section-by-Section Analysis)
A few commenters thought it would be appropriate to categorize the devices based on their maximum speed....
- seca 664 Digital Wheelchair Scale with Wireless Transmission
- Bradley OmniDeck with Oval Multipurpose Basin LD3010-HS-TO1
- Bradley OmniDeck with Rectangular Multipurpose Basin LD3010-HS-TR1
- TrueForm 30" ADA Floating Concrete Sink Wood Edge FLO-30W-ADA
- Bradley OmniDeck with Square Multipurpose Basin LD3010-HS-TS1
-
2.0 Methodology
” and “minimum” reach while the U.S. standards have only one range delimited by a minimum and a maximum value....
- GE® 30" Drop-In Electric Range JDS28DFWW
- Bradley Diplomat Foam Soap Dispenser 6A01-11
-
11B-705.1.2.3 Islands or cut-through medians
warnings at pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2 inches (51 mm) maximum...
-
Slope