Installs in minutes without tools, using waterproof silicone adhesive and 2-way tape (included) Housing constructed from durable, water-resistant ABS plastic Dimensions...
Search Results "Maximum Dimension"
- Better Living Signature Soap Dispenser 1
- Better Living Clear Choice Soap Dispenser 1
- Better Living Ulti-Mate Soap and Shower Dispenser 3 with Mirror
- GE® 30" Free-Standing Electric Range JB450RFSS
- Bobrick Narcotics Cabinet B-7316
- Door King Inc. 1812 Access Plus Communication System
- Panda S.81 All Aluminum Multi-Slide Door System
-
Clear Floor Space: ADA Standard Section 606.2
Section 606.2 covers the current ADA Standards for clear floor space at lavatories and sinks.
-
11B-703.3.2 Position
Braille shall be separated 3/8 inch (9.5 mm) minimum and ½ inch (12.7 mm) maximum from any other tactile characters and 3/8 inch (9.5 mm) minimum from raised borders and decorative elements...
-
11B-403.5.1 Clear width
Exceptions: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum for a length of 24 inches (610 mm) maximum provided that reduced width segments are separated...
-
11B-702.1 General
have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1), except that the maximum...
-
EQUIVALENT FACILITATION
Note: In determining equivalent facilitation, consideration shall be given to means that provide for the maximum independence of persons with disabilities while presenting the least risk...
-
11B-403.5.1 Clear width
Exceptions: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum for a length of 24 inches (610 mm) maximum provided that reduced width segments are separated...
-
11B-703.3.2 Position
Braille shall be separated 3/8 inch (9.5 mm) minimum and ½ inch (12.7 mm) maximum from any other tactile characters and 3/8 inch (9.5 mm) minimum from raised borders and decorative elements...
-
EQUIVALENT FACILITATION
Note: In determining equivalent facilitation, consideration shall be given to means that provide for the maximum independence of persons with disabilities while presenting the least risk...
-
11B-702.1 General
have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1), except that the maximum...
-
607.6 Shower Spray Unit and Water
Bathtub shower spray units shall deliver water that is 120°F (49°C) maximum. Advisory 607.6 Shower Spray Unit and Water....
-
1007.3.2 Golf Club Reach Range Area
All areas within holes where golf balls rest shall be within 36 inches (915 mm) maximum of a clear floor or ground space 36 inches (915 mm) wide minimum and 48 inches (1220 mm) long minimum...
-
1009.4.5 Grab Bars
The top of the gripping surface shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above transfer walls....
-
607.6 Shower Spray Unit and Water
Bathtub shower spray units shall deliver water that is 120°F (49°C) maximum. [ECTCR UFAS 4.20.6, 4.34.5.4(5)] Advisory 607.6 Shower Spray Unit and Water....
-
Entry Points and Seats
When play components are located on an accessible route, the height required to transfer directly to the entry point or seat of a play component has a minimum of 11 inches (280 mm) and a maximum...
-
1003.2.12.2 Opening limitations
Exception: The triangular opening formed by the riser, tread and bottom rail at the open side of a stairway shall be of a maximum size such that a sphere of 6 inches (152mm) in diameter...
-
SEAT HEIGHT MEASUREMENT DETAIL
Measuring to the top of the bolster would account for the maximum transfer height differential from a wheeled mobility device....