Exception: The triangular opening formed by the riser, tread and bottom rail at the open side of a stairway shall be of a maximum size such that a sphere of 6 inches (152mm) in diameter...
Search Results "Maximum Dimension"
-
1003.2.12.2 Opening limitations
-
SEAT HEIGHT MEASUREMENT DETAIL
Measuring to the top of the bolster would account for the maximum transfer height differential from a wheeled mobility device....
-
T502.4 Doorways with Steps on Over-the-Road Buses
Hinges and other door mechanisms shall be permitted to protrude 4 inches (100 mm) maximum into the door opening clear width at or below 48 inches (1220 mm) in height measured from the lowest...
-
3. EXCLUSIONS
Nevertheless, since the intended use of such excluded facilities may change with time or in emergencies, compliance with these DoD Standards is recommended to the maximum extent that is...
-
2.1.2.3 New York State Standards
Given a 1000 Hz signal at a level equal to the long-time average level of speech, the average value of the magnetic field should be 100 mA/meter +/- 3 dB between 100 to 8000 Hz, with a maximum...
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
The vertices of the triangle shall be located ¼ inch (6.4 mm) maximum from the edge of the circle....
-
ASME: ADA Standard Section 105.2.2
Section 105.2.2 of the ADA Standards cover references to the American Society of Mechanical Engineers (ASME) standards.
- BEA Inc. PBR45 Series Door Access 4.5" Round Push Plate (Push to Open)
- EZ-ACCESS Transitions® Modular Entry Mat
- BEA Inc. PBS45 Series Door Access 4.5" Square Push Plate (Push to Open)
- TownSteel THSP179 Standard Duty Spring Hinge
- Freedom Trax Motorized Track System
- Queue Solutions QueuePro Twin
-
Measures and Procedures
The space for the legs and feet has a fixed dimension of 14.5” deep by 22.5” wide (36.8x57.2cm)....
-
Utilities at Recreation Sites
Place elongated openings more than a quarter of an inch wide with the long dimension perpendicular to the primary direction of travel....
- Guardian Barrier-Free Safety Station with WideArea™ Eye/Face Wash GBF1909PCC
- Lutron Sivoia QED Kirbé Vertical Motorized Drapery System
-
UDI
All dimensions were taken to the extremes of the equipment including any object attached to the device like a ventilator....
- Assisted Living Directory - Connecticut Assisted Living Facilities & Senior Care
-
1008.2.4.1 Ground Level
The clear width of accessible routes shall be permitted to be 36 inches (915 mm) minimum for a distance of 60 inches (1525 mm) maximum provided that multiple reduced width segments are separated...
-
1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches (965 mm) maximum. EXCEPTIONS: 1....
-
702.1 General
have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1), except that the maximum...
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (12.7 mm) maximum within 10 inches (254 mm) horizontally of the minimum landing area...