(§404.2.4) D4 Is the area in front of the door level, with slopes no greater than 1:48 in all directions?...
Search Results "Enhanced 9-1-1"
Commonly Searched Documents
-
Section D: Entrances
-
Gangway Slope and Rise Exceptions
Gangway Slope and Rise Exceptions Gangways must be designed to provide for a maximum 1:12 (8.33%) slope but are not required to be longer than 30 feet in length....
-
B. Slopes
.: in the direction of travel) not more than 1:20 (critical dimension of 1 1/4" or less)?...
-
11B-406.5.3 Landings
The slope of the landing in all directions shall be 1:48 maximum. Exception: Parallel curb ramps shall not be required to comply with Section 11B-406.5.3....
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
floor units in non-elevator buildings shall be adaptable and on an accessible route unless an accessible route to the common (lobby) entrance is not required as determined by Test No. 1,...
-
1002.2 Accessible Routes
EXCEPTIONS: 1....
-
11B-703.2.7 Character spacing
Where characters have rectangular cross sections, spacing between individual raised characters shall be 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum....
-
703.3.1 Dimensions and Capitalization
Range Minimum in Inches Maximum in Inches Dot base diameter 0.059 (1.5 mm) to 0.063 (1.6 mm) Distance between two dots in the same cell 1...
-
1002.2 Accessible Routes
EXCEPTIONS: 1....
-
1002.2 Accessible Routes
EXCEPTIONS: 1....
-
1.2.6
Allowing a small percentage of localized slopes to exceed 8.3% is based on the allowable slopes in ADA/ABA - AG (2004) for existing buildings of 1:8 (12.5%) for maximum rises of 3 inches...
-
Changes in Level at Entry to Wheelchair Spaces (M303.3)
Level changes between ¼ inch high and ½ inch high would be required to be beveled with a slope not steeper than 1:2....
-
16. Opening Building Doors
should generally be granted as long as providing this assistance would not pose a direct threat, or leave the vehicle unattended or out of visual observation for a lengthy period of time.1...
- Wolf Cooktop Downdraft
-
11B-213.3 Plumbing fixtures and accessories
The 2013 California Plumbing Code (CPC), Table 4-1 provides minimum plumbing fixture requirements for new buildings, and changes of occupancy or use in an existing building resulting in...
-
1005.1 Accessible Routes
EXCEPTIONS: 1. Accessible routes serving floating fishing piers and platforms shall be permitted to use Exceptions 1, 2, 5, 6, 7 and 8 in 1003.2.1. 2....
-
5.8.2.7 Base Support Allowance
Base supports can be a maximum of 1½ inches high....
-
Floor [1014.3]
When the floor surface is constructed of asphalt, concrete, or boards, the slope of the floor surface must be no steeper than 1:48 (2 percent) in any direction, regardless of the type of...
-
1005.1 Accessible Routes
EXCEPTIONS: 1. Accessible routes serving floating fishing piers and platforms shall be permitted to use Exceptions 1, 2, 5, 6, 7 and 8 in 1003.2.1. 2....
-
§27.5 Definitions.
[44 FR 31468, May 31, 1979, as amended by Amdt. 1, 46 FR 37492, July 20, 1981; Amdt. 27-3, 51 FR 19017, May 23, 1986; 56 FR 45621, Sept. 6, 1991; 61 FR 32354, June 24, 1996; 61 FR 56424,...
-
1005.1 Accessible Routes
EXCEPTIONS: 1. Accessible routes serving floating fishing piers and platforms shall be permitted to use Exceptions 1, 2, 5, 6, 7 and 8 in 1003.2.1. 2....
-
§ 38.173(b)
station, the design of vehicles shall be coordinated with the boarding platform design such that the horizontal gap between a vehicle door at rest and the platform shall be no greater than 1...