The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
Search Results "End Transfer Surface"
Commonly Searched Documents
-
11B-609.3 Spacing
- Willoughby Industries WAW-2333 AquaWave® Three Station Solid Surface Lavatory System
- Willoughby Industries WAW-2322 AquaWave® Two Station Solid Surface Lavatory System
-
NOTES
Note that height measurement, as defined by the tables and chairs subcommittee, represents the highest point of the transfer surface, inclusive of bolsters, when measuring to the top of...
-
Construction and Manufacturing Tolerances: ADA Standard Section 104.1.1
Section 104.1.1 of the ADA Standards covers the most current information on dimensions in regards to construction and manufacturing tolerances in the ADA Standards.
-
Curb Ramps and Blended Transitions (R309.4) (Section-by-Section Analysis)
Parking spaces at the end of block face can be served by curb ramps or blended transitions at the pedestrian street crossing....
-
When Ramps Are Required
The balance of the elevated play components required to be on an accessible route may be connected by the ramp system, or by a transfer system....
-
Notes
U For instance, when patients are severely ill and need to be transported within a facility, staff will transfer them from their beds to the stretcher....
-
14. If an alteration is being made to part of a play area, does the entire play area need to be upgraded with accessible components and surfacing?
If an alteration is being made to part of a play area, does the entire play area need to be upgraded with accessible components and surfacing?...
-
¼ Inch Minus Limestone
The surface was installed in two rolled and compacted 3 inch lifts....
-
Areas for further work
Areas for further work In the process of assisting the various organizations that represent surface materials and professional groups the following issues were identified as parameters...
-
Observations:
The wheelchair scale we used had a leveled surface of length 30 in. long with a bevel of 5 in. each at both ends (i.e., total length of 40 in.)....
-
11B-809.10.5.1 Clear floor space
The edge of the clear floor space shall be flush with the control wall surface....
-
5. Medical Diagnostic Equipment
The standards address equipment that requires transfer from wheelchairs and other mobility aids and include requirements for transfer surfaces, support rails, armrests, compatibility with...
-
5. Medical Diagnostic Equipment
The standards address equipment that requires transfer from wheelchairs and other mobility aids and include requirements for transfer surfaces, support rails, armrests, compatibility with...
-
5. Medical Diagnostic Equipment
The standards address equipment that requires transfer from wheelchairs and other mobility aids and include requirements for transfer surfaces, support rails, armrests, compatibility with...
-
5. Medical Diagnostic Equipment
The standards address equipment that requires transfer from wheelchairs and other mobility aids and include requirements for transfer surfaces, support rails, armrests, compatibility with...
-
5. Medical Diagnostic Equipment
The standards address equipment that requires transfer from wheelchairs and other mobility aids and include requirements for transfer surfaces, support rails, armrests, compatibility with...
- Willoughby Industries WAW-2311 AquaWave® Single Station Solid Surface Lavatory System
-
The Limits of Utilizing a Cost-Benefit Analysis
To our knowledge there are no studies that provide a fully comprehensive analysis of the effects of the height of a transfer surface on people with various disabilities....
-
Notes
The Impact of Transfer Setup on the Performance of Independent Transfers: Final Report. Presentation to US Access Board. Washington, DC. 2011 2....
-
Clear Floor Space [4.16.2]
cannot swing into the clear floor space required at any fixture the 18 inch water closet centerline is absolute The 18 inch dimension is measured from the finished wall surface...
- Guldmann Basic High Sling
-
BACKGROUND
hospitals, and other medical settings.1 In response, the Access Board issued a notice of proposed rulemaking2 that, among other things, would specify a maximum lower adjustable height for the transfer...