This requirement applies to the means public entities use to meet their obligations under all provisions of this part....
Search Results "Pre-Construction Meeting"
Commonly Searched Documents
-
§ 37.5(i)(3) Public entity-public transport
-
Grab Bars: ADA Standard Section 604.5
Section 604.5 covers the current ADA Standards for grab bars that are used for water closets.
-
Door Swing: ADA Standard Section 603.2.3
Section 603.2.3 covers the current ADA Standards for door swings at clear floor space and clearances at fixtures in toilet and bathing rooms.
-
11B-213.3.6 Bathing facilities
permitted in transient lodging guest rooms, multi-bedroom housing units in undergraduate student housing and residential dwelling units; and shall not be permitted at other locations to meet...
-
Surfaces for Outdoor Recreation Access Routes
The surface of an outdoor recreation access route and the surface surrounding constructed features must be firm and stable. No exceptions are allowed....
- Keep Building Jackson
-
ADA Standards for Accessible Design Pocket Guide: ADA Standard Section 2010
The complete guide to the 2010 ADA Standards for Accessible Design with notes provided by national accessibility experts Evan Terry Associates
-
11B-224.7.2 Multi-bedroom housing units with adaptable features
. ◼ ETA Editor's Note The following Access Board Note was taken from ADA Title II §35.151(f) New Construction and Alterations; Housing at a Place of Education, and ADA Title...
-
F233.3.3 Alterations
is technically infeasible, or where it is technically infeasible to provide an accessible route to a residential dwelling unit, the Department of Defense shall be permitted to alter or construct...
-
238.3 Practice Putting Greens, Practice Teeing Grounds, and Teeing Stations at Driving Ranges
At least 5 percent, but no fewer than one, of practice putting greens, practice teeing grounds, and teeing stations at driving ranges shall be designed and constructed so that a golf car...
-
R202.3.1 Existing Physical Constraints
Where existing physical constraints make it impracticable for altered elements, spaces, or facilities to fully comply with the requirements for new construction, compliance is required to...
-
4(6)
(6) At the primary entry door to dwelling units with direct exterior access, outside landing surfaces constructed of impervious materials such as concrete, brick or flagstone, are no more...
-
1132A.4, Item 4
Secondary exterior doors onto decks, patios or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior...
-
1.9.1.4 Enforcing agency
State-funded tenant improvements to State-leased facilities, the local jurisdiction must be aware of DGS’ jurisdictional authority and DSA’s jurisdictional approvals necessary for State-funded construction...
-
11B-223.1.1.1 Area alterations
shall comply with Section 11B-805.2 until the number of patient bedrooms or resident sleeping rooms provided within the area of renovation complies with the minimum number required for new construction...
-
1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves
Where fire rings, grills, or fireplaces are constructed with raised edges or walls, the depth of the raised edge or wall is required to be 10 inches maximum....
-
Surface Smoothness
Recommendation: Avoid materials or construction methods that create bumpy and uneven surfaces in areas and along routes required to be accessible....
-
1.1.4
Complying with a tolerance of +0.8% is generally possible with common methods of constructing ramps with concrete, asphalt, and pavers....
-
11B-223.1.1.1 Area alterations
shall comply with Section 11B-805.2 until the number of patient bedrooms or resident sleeping rooms provided within the area of renovation complies with the minimum number required for new construction...
-
11B-223.1.1.1 Area alterations
shall comply with Section 11B-805.2 until the number of patient bedrooms or resident sleeping rooms provided within the area of renovation complies with the minimum number required for new construction...
-
TECHNICALLY INFEASIBLE
other existing physical or site constraints prohibit modification or addition of elements, spaces or features that are in full and strict compliance with the minimum requirements for new construction...
-
Location
The ADAAG L-shaped grab bar configuration that includes a bar on the sidewall and one on the rear wall behind the toilet was consistently considered inadequate to meet the needs of people...