(b) To the maximum extent feasible, all elements of the coordinated plan shall be submitted on January 26, 1992....
Search Results "Maximum Dimension"
-
§ 37.141(b)
-
11B-1008.2.5.2 Elevated
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
§ 38.23(b)(8) Platform entrance ramp
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, measured on level ground, for a maximum rise of 3 inches, and the transition from roadway or sidewalk...
-
11B-1008.2.5.2 Elevated
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
11B-405.3 Cross slope
Curved ramps are not prohibited by Chapter 11B; however, requirements for maximum slope and cross-slope cannot be exceeded. ◼...
-
407.4.8.2.1 Signal Type
EXCEPTION: For elevators other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum...
-
1009.2.1 Pool Lift Location
Where multiple pool lift locations are provided, no more than one pool lift shall be required to be located in an area where the water level is 48 inches (1220 mm) maximum....
-
Standards
deviation of 3mm in 3m, Class B has a maximum deviation of 6mm in 3m, and a Class C has a maximum deviation of 6 mm in 600 mm....
-
Shower Spray Unit
Comments also noted that delivered water should be "temperature limited" to the specified maximum (120 degrees) for consistency with American Society of Safety Engineers (ASSE) standards...
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
Height and Clearances [4.19.2]
Only a portion of the usable clear floor space can "count" as toe space, which is why a maximum depth and minimum height are specified for the front of the underlap of the required clear...
-
2.3.4 Analysis of Door Use Difficulty
The mean, median and range of WhMD user age, occupied width, occupied length and maximum power grip were also reported as we thought that these variables might help explain the door use...
-
4.26.3 STRUCTURAL STRENGTH
structural strength of grab bars, tub and shower seats, fasteners, and mounting devices shall meet the following specification: (1) Bending stress in a grab bar or seat induced by the maximum...
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
- Celia 2 Indoor/Outdoor Sconce by Hampstead
- Celia 1 Indoor/Outdoor Sconce by Hampstead
-
M301.2.1 Adjustability
A low transfer position at a height of 17 inches (430 mm) minimum and 19 inches (485 mm) maximum; B. A high transfer position at 25 inches (635 mm); and C....
-
§382.9(e)(1)
(1) If you submit a waiver request on or before September 10, 2008, the Department will, to the maximum extent feasible, respond to the request before May 13, 2009....
-
§382.133(b)
during air transportation to, from or within the United States, an electronic assistive device specified in paragraph (d) of this section on all aircraft originally designed to have a maximum...
-
§382.133(h)(1)
device in the aircraft cabin, within 48 hours of his/her making a reservation or 24 hours before the scheduled departure date of his/her flight, whichever date is earlier, of the expected maximum...
-
M302.2.1 Adjustability
A low transfer position at a height of 17 inches (430 mm) minimum and 19 inches (485 mm) maximum; B. A high transfer position at 25 inches (635 mm); and C....
-
404.2.11 Vision Lights
adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1090 mm) maximum...
-
403.5.1 Clear Width
EXCEPTION: The clear width shall be permitted to be reduced to 32 inches (815 mm) minimum for a length of 24 inches (610 mm) maximum provided that reduced width segments are separated by...