The exemption to the section 224.1.2 requirement for a 32-inch wide clearance at doors to shower and saunas applies only to those showers and saunas in guest rooms which are not required...
Search Results "Grab Bar Clearance"
-
Shower and Sauna Doors in Transient Lodging Facilities
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
- Rockwood Manufacturing Company 35 Push & Pull Bar Set 3/8" x 1-1/4" Door Hardware
-
F204.1 General
Within play areas, protruding objects on circulation paths shall not be required to comply with 307 provided that ground level accessible routes provide vertical clearance in compliance...
-
4.1.6(3)(c)(iii)
For example, an elevator of 47 in by 69 in (1195 mm by 1755 mm) with a door opening on the narrow dimension, could accommodate the standard wheelchair clearances shown in Figure 4....
-
4.2.6* Side Reach
If the side reach is over an obstruction, the reach and clearances shall be as shown in Fig 6(c)....
-
4.18.3 Clear Floor Space
Urinal shields that do not extend beyond the front edge of the urinal rim may be provided with 29 in (735 mm) clearance between them....
-
4.1.6(4)(d)
(i) Where existing elements prohibit strict compliance with the clearance requirements of 4.13.5, a projection of 5/8 in (16 mm) maximum will be permitted for the latch side door stop....
-
4.2.5 FORWARD REACH
If the high forward reach is over an obstruction, reach and clearances shall be as shown in Fig. 5(b). Figure 5 Forward Reach...
-
4.18.3 CLEAR FLOOR SPACE
Urinal shields that do not extend beyond the front edge of the urinal rim may be provided with 29 in (735 mm) clearance between them....
-
§ 38.159(a)(1) General
., lift or ramp) complying with paragraph (b) or (c) of this section and sufficient clearances to permit a wheelchair or other mobility aid user to reach a securement location....
-
204.1 General
Within play areas, protruding objects on circulation paths shall not be required to comply with 307 provided that ground level accessible routes provide vertical clearance in compliance...
- Pilot Rock FSDW-30 Campfire Ring
- Pilot Rock FS-30 Campfire Ring
- Pilot Rock N-20 Series Charcoal Grill
-
Current Accessibility Guidelines That Apply to the Forest Service
The Forest Service and those working with or for the Forest Service on National Forest System land must comply with the following enforceable guidelines and standards when designing,...
-
11B-704.5 TTY shelf
The shelf shall be capable of accommodating a TTY and shall have 6 inches (152 mm) minimum vertical clearance above the area where the TTY is to be placed....
-
704.5 TTY Shelf
The shelf shall be capable of accommodating a TTY and shall have 6 inches (150 mm) minimum vertical clearance above the area where the TTY is to be placed....
-
4.31.9(2)
The shelf shall be capable of accommodating a text telephone and shall have 6 in (152 mm) minimum vertical clearance in the area where the text telephone is to be placed....
-
4.10.9 Floor Plan of Elevator Cars
The clearance between the car platform sill and the edge of any hoistway landing shall be no greater than 1‒1/4 in (32 mm)....
-
4.10.9 FLOOR PLAN OF ELEVATOR CARS
The clearance between the car platform sill and the edge of any hoistway landing shall be no greater than 1-1/4 in (32 mm)....
-
Clear Floor or Ground Space and Turning Space
Clearances are required at accessible elements, fixtures, and controls so that people with disabilities, including those who use wheelchairs, can approach and use them....
-
11B-704.5 TTY shelf
The shelf shall be capable of accommodating a TTY and shall have 6 inches (152 mm) minimum vertical clearance above the area where the TTY is to be placed....