Users may slide off the seat and fall onto the floor of the shower while reaching for the shower controls and hand-held showerhead. Requirement: 4.21.2 Size and Clearances....
Search Results "Maximum Reach Depth"
-
Error/Omission: When a transfer shower is used, it is often larger than the required 36" x 36" size.
-
382.43 Must information and reservation services of carriers be accessible to individuals with hearing impairments?
We are also adding a new access requirement in §382.43(a)(4) to ensure that deaf and hard of hearing passengers are informed how to reach carriers by TTY: in any medium in which a carrier...
-
Typical examples of reasonable accommodations are:
Making sure materials and equipment are in easy reach for a factory worker who uses a wheelchair....
-
Serving Counters
If self-service condiments, utensils, or tableware are provided, then they should be located no higher than 54 inches if a side reach is possible or 48 inches for a forward reach (see Section...
-
SUMMARY OF THE 19-INCH RECOMMENDATION
subcommittee did maintain that 17 inches was preferred, and when this 19 inch recommendation was discussed with the full Advisory Committee on May 7th, 2013, the full committee was unable to reach...
-
11B-226.4 Baby changing tables
This has been generally understood to include the technical requirements for accessible routes, clear floor space, reach ranges, knee and toe space, worksurface heights, operable parts and...
-
6. EDUCATE YOUR COMMUNITY
Reach out to “force multipliers”— the organizations, businesses, and faith-based groups who can amplify your outreach efforts and reach the largest audience....
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
The vertices of the triangle shall be located ¼ inch (6.4 mm) maximum from the edge of the circle....
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
The vertices of the triangle shall be located ¼ inch (6.4 mm) maximum from the edge of the circle....
-
Guest Rooms
Interior hinged doors and gates: 5 pounds (22.2 N) Maximum. 2. Sliding or folding doors: 5 pounds (22.2 N) maximum. Advisory 404.2.7 Door and Gate Hardware....
- GE® 30" Slide-In Electric Convection Range JS750EFES
-
11B-706.4 Sound pressure level
Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB....
-
904.5.2 Tray Slides
The tops of tray slides shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground. [ECTCR UFAS 5.2]...
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
M305.3.2.1 Horizontal Position
The height of the top of the gripping surface on horizontal standing supports shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum above the standing surface....
-
602.7 Drinking Fountains for Standing Persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1090 mm) maximum above the finish floor or ground....
-
§ 1194.25(j)(2)
(2) Where any operable control is 10 inches or less behind the reference plane, the height shall be 54 inches maximum and 15 inches minimum above the floor....
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
706.4 Sound Pressure Level
Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB....
-
602.7 Drinking Fountains for Standing Persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1090 mm) maximum above the finish floor or ground....
-
1011.6 Water Spouts
Water spouts at water hydrants and water utility hook-ups shall be 28 inches (710 mm) minimum and 36 inches (915 mm) maximum above the ground....
-
609.2.1 Circular Cross Section
Grab bars with circular cross sections shall have an outside diameter of 1 1/4 inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
704.2.1.2 Forward Approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
Blended Transitions (R304.4) (Section-by-Section Analysis)
Blended Transitions (R304.4) (Section-by-Section Analysis) A maximum running slope of 5 percent is specified for blended transitions....