Objects with leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into...
Search Results "Maximum Reach Depth"
Commonly Searched Documents
-
11B-307.2 Protrusion limits
-
307.2 Protrusion Limits
Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into...
-
604.8.1.2 Doors
Where located in the front partition, the door opening shall be 4 inches (100 mm) maximum from the side wall or partition farthest from the water closet....
-
11B-703.4.1 Height above finish floor or ground
characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60 inches (1524 mm) maximum...
-
Elevator Exemption
The 500 square foot maximum was based on a floor area allowance of 100 square feet per occupant, which is consistent with model building code requirements for business and industrial occupancies...
-
Table Surface Height
Persons with disabilities considered the 34 inch maximum height too high for surfaces used for any length of time....
-
1009.5.7 Grab Bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above each step and transfer platform....
-
Transfer Supports Location and Configuration M301.3 and M302.3
Transfer Supports Location and Configuration M301.3 and M302.3 Location of the transfer supports shall be a minimum of 6 inches to a maximum of 19 inches from the top of the transfer...
-
R302.6.1 Pedestrian Street Crossings Without Yield or Stop Control
Where pedestrian access routes are contained within pedestrian street crossings without yield or stop control, the cross slope of the pedestrian access route shall be 5 percent maximum....
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
604.8.1.2 Doors
Where located in the front partition, the door opening shall be 4 inches (100 mm) maximum from the side wall or partition farthest from the water closet....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
11B-812.10.4 Location
circulation path is not provided adjacent to the head end of the vehicle space or access aisle, the EV charger may be located within the projected width of the access aisle 36 inches (914 mm) maximum...
- Apex Challenge Circuit CH7000
-
11B-406.3.2 Turning space
The slope of the turning space in all directions shall be 1:48 maximum. FIGURE 11B-406.3.2 ‡‡ PARALLEL CURB RAMPS...
-
1008.2.5.3.1 Handrail Gripping Surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
M101.1 Purpose
The MDE Standards provide for independent access to, and use of, diagnostic equipment by patients with disabilities to the maximum extent possible....
-
1008.2.5.3.1 Handrail Gripping Surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
Museum Gift Shop
The 42" height of the main cashier counter and the 42 1/2" height of the second cashier counter exceed the maximum 36" allowable height above the finished floor....
-
Sec.36.402(a)(1)
(1) Any alteration to a place of public accommodation or a commercial facility, after January 26, 1992, shall be made so as to ensure that, to the maximum extent feasible, the altered portions...
-
§ 36.402(a)(1)
(1) Any alteration to a place of public accommodation or a commercial facility, after January 26, 1992, shall be made so as to ensure that, to the maximum extent feasible, the altered portions...
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
5.1.5 Floor Height
Where the floor at the entrance to the camp shelter is elevated above the ground surface, the floor shall be 17 (430 mm) high minimum to 19 inches (485 mm) high maximum measured from the...
-
Reading and Study Areas [8.2]
Recommendation: Specifications in 4.32, including clear passage for accessible routes, knee clearances and surface height (34 inch maximum) should be considered for movable furnishings as...