Fixed elements for public use, such as service buzzers and ticket number dispensers, need to be within accessible reach ranges and on an accessible route....
Search Results "Maximum Reach Depth"
Commonly Searched Documents
-
Other Counters/ Teller Windows [7.2(2)]
-
Tandem Bicycles
Most tandem bicycles are similar to upright single bikes where riders sit on a small saddle and reach forward to handlebars that are typically at or slightly above or below the seat height...
-
Roughness Calculation
If the crack depth was deep enough, the wheel would be suspended by the two sides of the surface and never hit the bottom as shown in Figure 122 {sic}....
-
Top Landings
The proposed rule specified that side flares of 1:12 maximum must be provided when space at the top of curb ramps is less than 48 inches long. This specification has been removed....
-
Elevated Accessible Routes
inch (915 mm) clear width 32-inch (815 mm) narrowed width permitted for 24-inch (610 mm) length to accommodate features in the composite structure 12-inch (305 mm) rise maximum...
-
Play Tables
17 inches (430 mm) deep minimum Play tables designed primarily for children under 5 years old may provide a parallel approach instead of knee clearance if the rim is a maximum...
-
405.2 Slope
Table 405.2 Maximum Ramp Slope and Rise for Existing Sites, Buildings, and Facilities Slope1 Maximum Rise Steeper than 1:10 but not steeper than 1:8 3...
-
11B-604 Water closets and toilet compartments
INTERPRETATION Showers are fixtures including a 30 inch x 60 inch clear receptor with a minimum/maximum slope of ¼ inch per foot to a drain (refer to CPC Section 408.5 and CBC Section...
-
405.2 Slope
Table 405.2 Maximum Ramp Slope and Rise for Existing Sites, Buildings, and Facilities Slope¹ Maximum Rise Steeper than 1:10 but not...
-
711.3.1 Through penetrations
space between the penetrating item and the fire-resistance- rated wall shall be permitted to be protected as follows: In concrete or masonry walls where the penetrating item is a maximum...
-
405.2 Slope
Table 405.2 Maximum Ramp Slope and Rise for Existing Sites, Buildings, and Facilities Slope1 Maximum Rise Steeper than 1:10 but not...
-
608.6 Shower Spray Unit and Water
Shower spray units shall deliver water that is 120°F (49°C) maximum....
-
Gratings [4.5.4]
ADAAG requires a maximum opening dimension of ½ inch in one direction and that elongated openings be placed so that the long dimension is perpendicular to the dominant direction of travel...
-
608.6 Shower Spray Unit and Water
Shower spray units shall deliver water that is 120°F (49°C) maximum....
-
Calculation of Percentages
For dimensions not expressed as an absolute (“X maximum” or “Y minimum”), specify in a manner that accommodates the expected tolerance within the required dimensions by subtracting the tolerance...
-
11B-608.5.2 Standard roll-in type shower compartments
compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm) minimum and 27 inches (686 mm) maximum...
-
Currently, the DCFC time limit is 30 minutes maximum. New larger battery capacity will take longer to get 80% charge – i.e. Chevy Bolt EV, Tesla Model 3, 2018 Nissan LEAF, etc. Can we reconsider the time limit?
RESPONSE: The 30 minute time limit applies to drive-up EVCS of any type. This design option allows brief charging and queuing for charging service, and does not consider that...
-
Conclusions
The polyurethanes exhibited higher G values overall (in comparison to EWF, silicone- and latex-stabilized EWF) and only the polyurethanes exceeded 100, but none exceeded the maximum allowed...
- GE® 30" Drop-In Electric Range JDS28DFWW
- VE CONNECT Smart Vending Machine
- Kawneer North America 2000T Terrace Doors
-
1008.2.5.3.1 Handrail Gripping Surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
A1
Is a relatively level (1:50 or 2% maximum slope in all directions) access aisle provided adjacent and parallel to the side of the vehicle pull-up area?...
-
1009.2.4 Seat Height
The height of the lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the...