Where handrails are provided along walking surfaces with running slopes not steeper than 1:20 they shall comply with 505. Advisory 403.6 Handrails....
Search Results "Floor Slope"
Commonly Searched Documents
-
403.6 Handrails
-
Grade
This may be expressed as the percentage of change in elevation (grade) or as a ratio of vertical distance to horizontal distance (running slope)....
-
11B-1009.2.2 Seat location
The deck surface between the centerline of the seat and the pool edge shall have a slope not steeper than 1:48....
-
CURB RAMP
A sloping pedestrian way, intended for pedestrian traffic, which provides access between a walk or sidewalk and a surface located above or below an adjacent curb face....
-
11B-1009.2.2 Seat location
The deck surface between the centerline of the seat and the pool edge shall have a slope not steeper than 1:48....
-
11B-206.2.3.2 Distance to Elevators
In new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via...
-
11B-225.2.3 Library book stacks
Book stacks available for public use shall be 54 inches (1372 mm) maximum above the finish floor....
-
11B-206.7.5 Existing site constraints
For example, a new building constructed between and connected to two existing buildings may have insufficient space to coordinate floor levels and also to provide ramped entry from the public...
-
Additional Clearance: ADA Standard Section 306.2.4
Section 306.2.4 covers the current ADA Standards for additional clearances for toe space.
-
Leveling: ADA Standard Section 407.4.4
Section 407.4.4 covers the current ADA Standards for the self-leveling feature in elevator cars.
-
11B-407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of ½ inch (12.7 mm) under rated loading to...
-
11B-306.2.4 Additional clearance
Space extending greater than 6 inches (152 mm) beyond the available knee clearance at 9 inches (229 mm) above the finish floor or ground shall not be considered toe clearance....
-
11B-804.2.3 Turning space
In kitchens within multi-bedroom housing units and on floors containing accessible sleeping rooms with adaptable features in undergraduate student housing, turning spaces complying with...
-
STORY
That portion of a building or facility designed for human occupancy included between the upper surface of a floor and upper surface of the floor or roof next above....
-
STORY
[DSA-AC] That portion of a building or facility designed for human occupancy included between the upper surface of a floor and upper surface of the floor or roof next above....
-
R304.5.2 Grade Breaks
Surface slopes that meet at grade breaks shall be flush....
-
Section 4.9.4
• Section 4.9.4 of the 1991 Standards requires handrails at the bottom of stairs to continue to slope for a distance of the width of one tread beyond the bottom riser nosing and to further...
-
Temporary Solutions For Emergency Sheltering - Ramps
Suggestion: Install a portable ramp with a slope no steeper than 1:12 with edge protection. Store the portable ramp on site so it can be easily accessed in an emergency....
-
B) Accessible Route
An accessible route must be at least 36 inches wide, have no abrupt vertical changes in level (such as a step), have a running slope no more than 1:12 in most cases, and meet other requirements...
-
Instrumentation for Analysis
An on-site inspection form (Appendix C) was created to collect information on the nine locations identifying deficiencies in slope, cross slope, changes in level and openings in the surface...
-
Curb or Barrier: ADA Standard Section 405.9.2
Section 405.9.2 covers the current ADA Standards for a curb or barrier that is provided as edge protection at a ramp.
-
403 Walking Surfaces
The requirements for walking surfaces derive from existing specifications for accessible routes covering floor or ground surfaces, slope, changes in level, and clearances....
-
11B-406.3.2 Turning space
The slope of the turning space in all directions shall be 1:48 maximum. FIGURE 11B-406.3.2 ‡‡ PARALLEL CURB RAMPS...