Is it mounted with the coin slot no higher than 54" above the floor, and one pay phone on that floor with the highest operable element no higher than 48" above the floor?...
Search Results "Floor Slope"
Commonly Searched Documents
-
Coin Slot Height
-
Passing Spaces [1016.4]
When passing spaces and resting intervals overlap, the technical requirements for resting intervals apply and the slope of the surface must be no steeper than 1:48 (2 percent) in any direction...
-
11B-406.5.3 Landings
The slope of the landing in all directions shall be 1:48 maximum. [2010 ADA Standards] 406.4 Landings. Landings shall be provided at the tops of curb ramps....
-
11B-504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
Treads and Risers [4.9.2], Nosings [4.9.3]
Angled or rounded nosings or sloped risers help prevent this hazard and provide a smoother transition. Straight risers without nosings are acceptable....
-
F216.13 Trailhead Signs
requirements in 1017.11 require the signs to include information on the length of the trail or trail segment; surface type; typical and minimum tread width; typical and minimum running slope...
-
11B-504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
11B-504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
- Willoughby Industries ASHS-1013-06-15-HC Ligature-Resistant 15" wide Lavatory
- Sargent 8200 Mortise Lock with BHL Trim
-
Height and Depth: ADA Standard Section 605.2
Section 605.2 covers the current ADA Standards for the height and depth of urinals.
-
11B.707.7.1.3 Horizontally mounted display screen
from the viewer 60 degrees to 90 degrees (horizontal) from vertical, the center line of the display screen and other display devices shall be no more than 34 inches (864 mm) above the floor...
-
11B-605.2 Height and depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground....
-
11B-203.14 Raised diving boards and diving platforms
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
1.15 Stadium-style seating, stadium section, or stadium seating
Each row of stadium seating is elevated above the row immediately ahead of it and is accessed by stepped, rather than sloped, aisles....
-
C. M303 Diagnostic Equipment Used by Patients Seated in a Wheelchair
Board made four significant changes to this section: two significant changes to accommodate the unique challenges of mammography equipment; one significant change to the ramped running slope...
-
K. Eating Areas
Eating Areas An accessible route, at least 36 inches wide and without steps or steep slopes, must be provided to and throughout the food service and eating areas of the shelter....
-
7.4.9 Trail Facilities
When the surface of the required clear ground space for trail facilities is not paved or is not elevated above the natural ground, slopes not steeper than 1:20 (5 percent) shall be permitted...
-
Where Ramps and Curb Ramps are Required [ยง303.4]
Portions of accessible routes with running slopes steeper than 5% also must be treated as ramps....
-
1132A.4, Item 4
., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25.4 mm), provided a ramp with a maximum slope of 1:8 is permanently installed....
-
11B-403.6 Handrails
Where handrails are provided along walking surfaces with running slopes not steeper than 1:20 they shall comply with Section 11B-505. Advisory 11B-403.6 Handrails....