5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms Recommendations Description: Entry to wheelchair spaces on raised surfaces greater than ¼ inch in height requires a...
Search Results "MDE: Medical Diagnostic Equipment"
Commonly Searched Documents
-
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms
-
5.9.2 Standing Supports on Ramped Entry Raised Platforms with Wheelchair Spaces
5.9.2 Standing Supports on Ramped Entry Raised Platforms with Wheelchair Spaces.
-
5.9.2 Standing Supports on Ramped Entry Raised Platforms with Wheelchair Spaces Recommendations
5.9.2 Standing Supports on Ramped Entry Raised Platforms with Wheelchair Spaces Recommendations
-
Figure M5: Overview of M303 Diagnostic Equipment for Use by a Patient While Seated in a Wheelchair and 304 Diagnostic Equipment for Use by a Patient in a Standing Position (Mammography Machine Example)
Where the primary use of the equipment supports more than one patient position, it must comply with the requirements for each use. ...
-
3. Exception to Ramp Running Slope
The MDE Advisory Committee, during its discussion of wheelchair spaces on weight scales, extensively addressed the permissible slopes of ramps on raised platforms....
-
M303.2.6 Edge Protection
inches (38 mm) in height, edge protection 2 inches (51 mm) high minimum measured from the surface of the platform shall be provided on each side not providing entry to or exit from the equipment...
-
M303.2.2 Width
Wheelchair spaces shall be 36 inches (915 mm) wide minimum. EXCEPTION: Wheelchair spaces located on raised platforms shall be permitted to be 32 inches (815 mm) wide minimum to a...
-
M303.3.1 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical.
-
M303.3.2 Beveled
Changes in level between ¼ inch (6.4 mm) high and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2.
-
M303.1 General (Section-by-Section Analysis)
This is an introductory section.
-
M303.2.4 Knee and Toe Clearance
Wheelchair spaces shall include knee and toe clearance complying with M303.2.4. The depth of the wheelchair space shall include knee and toe clearance of 17 inches (430 mm) minimum...
-
M303.3.1 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical.
-
M303.3.2 Beveled
Changes in level between ¼ inch (6.4 mm) high and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2.
-
5.8.2 Knee and Toe Clearance Recommendations under Breast Platform Recommendations
Knee and toe clearances are critical where patients seated in a wheelchair need to position their knees and toes next to or underneath a component of the diagnostic equipment....
-
Medical Diagnostic Equipment Accessibility Standards Sub-Committee Recommendations Imaging Equipment
Accessibility Standards for Medical Diagnostic Equipment Medical Diagnostic Equipment Accessibility Standards Sub-Committee Recommendations - Imaging Equipment Final Report June...
-
5.8.2.8 Knee and Toe Clearance Recommendations Summary
toe clearance recommendations in sections 5.8.2.1 – 5.8.2.7 are summarized below, in Figure 5.8.2.8, which shows the measurements needed to determine if a certain piece of mammography equipment...
-
1. Standing Supports
One commenter, a medical association, indicated that standing supports for imaging equipment vary widely based on the type of environment and specific imaging equipment being used....
-
General: ADA Standard Section 236.1
Section 236.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for exercise machines and equipment.
- Midmark 625 Barrier-Free® Power Examination Table
- Midmark 623 Barrier-Free® Power Examination Table
- Midmark Ritter 222 Barrier-Free® Power Examination Table
- Midmark Ritter 223 Barrier-Free® Power Examination Table
- Brewer AssistPRO™ Power Procedure Table
- Brewer Assist Power Procedure Table