407.3.3.3 Duration. Door reopening devices shall remain effective for 20 seconds minimum.
Search Results "Elevator Hoistway"
-
407.3.3.3 Duration
-
407.3.3.2 Contact
407.3.3.2 Contact. The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses.
-
407.3.3.1 Height
407.3.3.1 Height. The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish...
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
11B-407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum.
-
11B-407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum.
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
11B-407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses.
-
11B-407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum.
-
11B-407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses.
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
Elevators: ADA Standard Section 206.6
Section 206.6 covers scoping requirements in the most current ADA Standards for accessible routes to elevators.
-
11B-411.2.2 Elevator car identification at elevator landings
Elevator car identification shall comply with Section 11B-411.2.2....
-
11B-411.2.2 Elevator car identification at elevator landings
Elevator car identification shall comply with Section 11B-411.2.2....
-
11B-206.6 Elevators
Elevators provided for passengers shall comply with Section 11B-407. Where multiple elevators are provided, each elevator shall comply with Section 11B-407....
-
11B-206.6 Elevators
Elevators provided for passengers shall comply with Section 11B-407. Where multiple elevators are provided, each elevator shall comply with Section 11B-407....
-
11B-407.4 Elevator car requirements
Elevator cars shall comply with Section 11B-407.4....
-
11B-407.4 Elevator car requirements
Elevator cars shall comply with Section 11B-407.4....
-
11B-411.2 Elevator landing requirements
Elevator landings shall comply with Section 11B-411.2....
-
11B-411.2 Elevator landing requirements
Elevator landings shall comply with Section 11B-411.2....
-
Floor Designations
The proposed rule specified that tactile floor designations at the hoistway be 60 inches above the floor, measured from the baseline of the characters (407.2.4)....
-
Elevators: ADA Standard Section 407
Section 407 covers the current ADA Standards for elevators.
-
11B-411.4.6 Elevator car controls
Where provided, elevator car controls shall comply with Sections 11B-411.4.6 and 11B-309.4....
-
11B-411.4.6 Elevator car controls