Section 409.3.2 covers the current ADA Standards for the location of private residence elevator doors.
Search Results "Elevator Hoistway"
Commonly Searched Documents
-
Location: ADA Standard Section 409.3.2
-
409.3.1 Power Operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in...
-
11B-411.2.1.7 Elevator car assignment
When the accessibility function button is pressed, elevator car assignment shall comply with Section 11B-411.2.1.7....
-
Raised and Braille Characters on Hoistway Entrances [4.10.5]
Raised and Braille floor designations are required on both jambs, with the centerline 60 inches from the finished floor. Raised characters must be 2 inches high. Braille characters...
-
407.2.3.1 Floor Designation
Floor designations complying with 703.2 and 703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
Elevator Landing Requirements [§407.2]
Elevator Landing Requirements [§407.2]...
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
407.2.3.1 Floor Designation
Floor designations complying with 703.2 and 703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
11B-407.2.2.1 Visible and audible signals
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car’s direction of travel....
- Elvoron LU/LA - Limited Use / Limited Application Hydraulic Elevator
-
11B-407.2.3.1 Floor designation
Floor designations complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
1009.6.2 Stairway or elevator access
Every required area of refuge shall have direct access to a stairway complying with Sections 1009.3 and 1023 or an elevator complying with Section 1009.4....
-
Location: ADA Standard Section 407.4.6.1
Section 407.4.6.1 covers the current ADA Standards for the location of elevator car controls.
-
Buttons: ADA Standard Section 407.4.6.2
Section 407.4.6.2 covers the current ADA Standards for the elevator car control buttons.
-
Car Dimensions: ADA Standard Section 407.4.1
Section 407.4.1 covers the current ADA Standards for elevator car dimensions.
-
407.2.3.1 Floor Designation
Floor designations complying with 703.2 and 703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
Elevated Play Components: ADA Standard Section 240.2.2
Section 240.2.2 covers scoping requirements in the current ADA Standards for elevated play components.
-
Floor Surfaces: ADA Standard Section 407.4.2
Section 407.4.2 covers the current ADA Standards for the floor surfaces of elevator cars.
-
Destination Indicator: ADA Standard Section 407.4.8.1.4
Section 407.4.8.1.4 covers the current ADA Standards for visible elevator destination indicators.
-
11B-407.2.3.1 Floor designation
Floor designations complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
11B-407.2.3.1 Floor designation
Floor designations complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
Platform to Runway Clearance: ADA Standard Section 410.4
Section 410.4 covers the current ADA Standards for the required clearance between the platform and any runway landing.
-
11B-410.4 Platform to runway clearance
The clearance between the platform sill and the edge of any runway landing shall be 1¼ inch (32 mm) maximum.
-
Elevated: ADA Standard Section 1008.2.4.2
The clear width of accessible routes connecting elevated play components shall be 36 inches (915 mm) minimum. EXCEPTIONS: 1....