What does "one of each type" mean in a store where computerized check-out permits universal service at any cash register?...
Search Results "Break Out Opening"
Commonly Searched Documents
-
III-7.8400 Business and mercantile
-
Toilet Rooms South (Briefing Theater)
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). kk....
-
Sections 5 Through 9 (Preamble, Section-by-Section Analysis)
., Check-out Aisles, provides that, in new construction, a certain number of each design of check-out aisle, as listed in a chart based on the total number of checkout aisles of each design...
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum....
-
Toilet Rooms North (Celebrity Spies)–Men [sic]
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). ee....
-
Door Closers [4.13.10]
Door Closers [4.13.10] Because it may be difficult for a person with a disability to open a door against the resistance offered by a closer, it is important that the closing action be...
-
§ 36.303(g)(10)
(10) This section does not require the use of open movie captioning as a means of compliance with paragraph (g) of this section, even if providing closed movie captioning for digital movies...
-
1132A.6 Closer-effort to operate doors
1132A.6 Closer-effort to operate doors. Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push...
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to...
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to...
-
§382.57(c)(5)(iii) Captioning
Multimedia content that contains speech or other audio information necessary for the comprehension of the content must be open or closed captioned....
-
§ 382.57(c)(5)(iii) Captioning
Multimedia content that contains speech or other audio information necessary for the comprehension of the content must be open or closed captioned....
-
§ 38.95(b)(7) Platform gaps
Any openings between the lift platform surface and the raised barriers shall not exceed 5/8 inch wide....
-
Section 36.303(g)(10)
Section 36.303(g)(10) in the final rule provides that “[t]his section does not require the use of open movie captioning as a means of compliance with paragraph (g), even if providing closed...
-
Comparison of Single-User Toilet Room Layouts: 1A, 1B, and 1C
Comparison of Single-User Toilet Room Layouts: 1A, 1B, and 1C 1991 Standards Plan-1A: 1991 Standards Minimum with Out-Swinging Door 5’-0" x 7’-3"...
-
§ 38.83(b)(7) Platform gaps
Any openings between the lift platform surface and the raised barriers shall not exceed 5/8 inch wide....
-
§ 38.23(b)(7) Platform gaps
Any openings between the platform surface and the raised barriers shall not exceed 5/8 inch in width....
-
Comparison of Single-User Toilet Room “Pairs” With Fixtures Side-by-Side: Plan 1A and Plan 1B
Comparison of Single-User Toilet Room “Pairs” With Fixtures Side-by-Side: Plan 1A and Plan 1B 1991 Standards Plan-1A Pair: 1991 Standards with Out-Swinging...
-
Exterior/ Fire Doors
Considering that closing force is 60% efficient, a 15 Ib maximum for opening force provides 9 lb for closure and latching, which may be sufficient for most doors....
-
Toilet Rooms-Banquet Area
The force required to push or pull open the doors to the women's and men's toilet rooms designated as accessible is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf...
-
Clear Width: ADA Standard Section 404.2.3
Section 404.2.3 covers the current ADA Standards for clear width at manual doors, doorways and manual gates that are part of an accessible route.
-
11B-404.2.3 Clear width
Door openings shall provide a clear width of 32 inches (813 mm) minimum....