[See subsections ...]
Search Results "Break Out Opening"
Commonly Searched Documents
-
11B-904 Check-out aisles and sales and service counters
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
- Open Doors Organization (ODO)
-
11B-404.2.9 Door and gate opening force
SECTION TITLE NOTES 11B-404.2.9 Door and gate opening force....
-
7d.
Is no more than 5 pounds force needed to push or pull open the accessible door?...
-
g-iv
Is no more than 5 pounds force needed to push or pull open the door?...
-
4.5.6 Openings
Openings in the clear floor or ground space surface shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter....
-
3.4.7 Openings
Openings in the clear ground space and turning space surface shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter....
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1. TABLE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND...
-
A4.13.11(1) Hinged doors
(1) Hinged doors: Force applied perpendicular to the door at the door opener or 30 in (760 mm) from the hinged side, whichever is farther from the hinge....
-
A4.13.11(1) Hinged doors
(1) Hinged doors: Forced applied perpendicular to the door at the door opener or 30 in (760 mm) from the hinged side, whichever is farther from the hinge....
-
4.5.4 Gratings
If gratings have elongated openings, then they shall be placed so that the long dimension is perpendicular to the dominant direction of travel (see Fig. 8(h))....
-
4.5.4 GRATINGS
If gratings have elongated openings, then they shall be placed so that the long dimension is perpendicular to the dominant direction of travel (see Fig. 8(h))....
-
404.2.9 Door and Gate Opening Force
404.2.9 Door and Gate Opening Force. Fire doors shall have a minimum opening force allowable by the appropriate administrative authority....
-
Opening Force [§404.2.9]
Opening Force [§404.2.9] The maximum 5 lbf opening force applies to all accessible doors and gates except: fire doors (minimum opening force allowed by code) exterior...
-
C. Availability of Captioning and Audio Description
Currently, captioning is delivered to patrons in one of two formats: “open” and “closed.”...
-
904.3.1 Aisle
Aisles shall comply with 403.
-
11B-904.3.1 Aisle
Aisles shall comply with Section 11B-403.
-
904.3.1 Aisle
Aisles shall comply with 403.
-
904.3.1 Aisle
904.3.1 Aisle. Aisles shall comply with 403.
-
11B-904.3.1 Aisle
Aisles shall comply with Section 11B-403.
-
11B-904.3.1 Aisle
Aisles shall comply with Section 11B-403.
-
d. i.
Provide doors that require no more than 5 lbf to push or pull open at the following locations: (1) Spy City Café men's and women's toilet rooms; (2) Main Lobby restrooms vestibule;...
-
11B-904.3.4 Identification sign
When not all check-out aisles are accessible, accessible check-out aisles shall be identified by a sign clearly visible to a person in a wheelchair displaying the International Symbol of...