Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character....
Search Results "Ground Floor Exit"
-
11B-703.8.9 Height above floor
-
SECOND FLOOR
SECOND FLOOR...
-
THIRD FLOOR
THIRD FLOOR...
-
FIRST FLOOR
FIRST FLOOR...
-
1008.2.4.1 Ground Level
1008.2.4.1 Ground Level. At ground level, the clear width of accessible routes shall be 60 inches (1525 mm) minimum. EXCEPTIONS: 1....
-
2.3 Restrooms
Are the restrooms accessible? Is the entry door at least 32 inches wide? Is there a larger stall or an area in the restroom at least 36 inches in...
-
A4.16.4 Grab Bars
Fig. A6(a) and (b) show the diagonal and side approaches most commonly used to transfer from a wheelchair to a water closet. Some wheelchair users can transfer from the front of the...
-
A4.16.4 GRAB BARS
Fig. A5(a) and (b) show the diagonal and side approaches most commonly used to transfer from a wheelchair to a water closet. Some wheelchair users can transfer from the front of the...
-
Attachment I
There is no accessible emergency exit. Provide an accessible emergency exit. Standards §§ 4.1.6(1)(b), 4.1.3(9), 4.3.11....
- Allegion Falcon 19 Series Exit Devices
-
Accessible Sidewalks 2: Pedestrians with Ambulatory Impairments
Requires the Registered User plan or above. Login!
-
Maneuvering Space, Adjustable Cabinetry, Fixtures and Plumbing
sufficient maneuvering space is provided within the bathroom for a person using a wheelchair or other assistive device to enter and close the door, use the fixtures, reopen the door and exit...
- Sargent AL 80 Alarmed Exit Panic Door Hardware
- Allegion Falcon 2090 Cross Bar Exit Device
- Sargent 8888 Reversible Rim Exit Device
- Mobi-Mat® Recpath™ ADA Beach Access Mat
- Sargent NB8700 Top Latch Surface Vertical Rod Exit Device
-
Ground-Level Accessible Routes
Ground-Level Accessible Routes A ground-level accessible route connects play components at ground level. 60 inches (1525 mm) minimum clear width 1:16 maximum slope ...
-
224 Transient Lodging Guest Rooms
(1) Kitchens within housing units containing accessible sleeping rooms with mobility features (including suites and clustered sleeping rooms) or on floors containing accessible sleeping...
-
A4.17.3 Size and Arrangement
This section requires use of the 60 in (1525 mm) standard stall (Figure 30(a)) and permits the 36 in (915 mm) or 48 in (1220 mm) wide alternate stall (Figure 30(b)) only in...
- Access Board: Tactile Sign Raised Character Requirements