permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum above the floor...
Search Results "Ground Floor Exit"
Commonly Searched Documents
-
Permitted Protrusions in Wheelchair Spaces: ADA Standard Section 1002.4.4.3
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor...
- Access Board: Signs
- Allegion Von Duprin 55 Series Cross Bar Exit Devices
-
11B-703.8.9 Height above floor
Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character....
-
11B-405.9.2 Curb or barrier
A curb or barrier shall be provided that prevents the passage of a 4-inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor or ground...
-
Applying the Accessibility Standards to the Plan, Installation, and Maintenance of Ground Level Accessible Routes for Playgrounds
Is the running slope for the ground level accessible route less than 1:16 or 6.25%? Is the maximum cross slope for the ground level accessible route less than 1:48 or 2.08%?...
- Tormax Technologies iMotion® TN 110 In-Floor Swing Door Operator (High and Low Energy)
-
Clear Width: ADA Standard Section 404.2.3
Section 404.2.3 covers the current ADA Standards for clear width at manual doors, doorways and manual gates that are part of an accessible route.
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
5.8.2.6 Clearance Depth at Toe Height above the ground Recommendation
5.8.2.6 Clearance Depth at Toe Height above the ground Recommendation The Committee recommends 22 inches minimum clearance depth at toe height....
-
Spout Height: ADA Standard Section 602.4
Section 602.4 covers the current ADA Standards for the spout height of drinking fountains.
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground....
-
Attachment E
toilet room that is currently designated for people with disabilities is not accessible because the door swings into the single user toilet room and encroaches upon the required clear floor...
- SmartCells Flooring: Fall Protection Technology on Global BC News Hour (Canada)
- Whitehall Mfg. WH2142W2 Ligature-Resistant Toilet Wall Supply On-Floor Wall Waste
- Guide for Home Remodeling for People with Disabilities and Special Needs: What You Need to Know
-
Associated
Associated TAS 604.3.2 allows “associated” grab bars, dispensers, sanitary napkin disposal units, coat hooks, and shelves to overlap the required clearance around an accessible...
-
Fishing Facilities
Word Fillable Form (0.8MB) Word Non-Fillable Form (0.8MB) PDF Non-Fillable Form (0.7MB)
-
Scoping [4.1.3(8)]
accessible according to two sets of criteria that must be met separately: 1) the minimum number of accessible building or facility entrances must equal or exceed the number of required exits...