This document, portion of document or clip from legal proceedings may not represent all of the facts, documents, opinions, judgments or other information that is pertinent to this case. The entire case, including all court records, expert reports, etc. should be reviewed together and a qualified attorney consulted before any interpretation is made about how to apply this information to any specific circumstances.

THIRD FLOOR

Disinformation Corridor Exhibit:

z. The force required to push or pull open the red door leading out of the exhibit is 15 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b).

Rising Sun Exhibit:

aa. The force required to push or pull open the painted door leading out of the exhibit is 14 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b).

Briefing Room Theater:

bb. The theater lacks the required integrated wheelchair seating areas for two wheelchairs and two companion seats. See Standards §§ 4.1.13(19)(a) and 4.33.3.

Cloak and Dagger Theater:

cc. The theater lacks the required integrated wheelchair seating area for two wheelchairs and two companion seats. See Standards §§ 4.1.3(19)(a) and 4.33.3.

Toilet Rooms North (Celebrity Spies)–Men [sic]:

dd. The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b).

ee. The men's toilet room stall door hardware requires tight grasping and twisting of the wrist. See Standards § 4.13.9.

Toilet Rooms North (Celebrity Spies)–Women [sic]:

ff. The force required to push or pull open the women's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b).

gg. The women's toilet room stall door hardware requires tight grasping and twisting of the wrist. See Standards § 4.13.9.

hh. The operation of the feminine product dispenser in the women's toilet room requires tight grasping and twisting of the wrist. See Standards § 4.27.4.

ii. The toilet seat is 20" above the finished floor and exceeds the allowable range of 17" to 19". See Standards § 4.16.3.

Toilet Rooms South (Briefing Theater):

jj. The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b).

kk. The men's and women's toilet room stall door hardware requires tight grasping and twisting of the wrist. See Standards § 4.13.9.

ll. The force required to push or pull open the women's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b).