Where 20 or more elevated play components are provided, ramps must connect to a minimum of 25% of the elevated play components. ...
Search Results "Curb Ramp Slope"
Commonly Searched Documents
-
STEP 4 Assess how to get there
-
A4.1.3(5)
Under Exception 4, platform lifts are allowed where existing conditions make it impractical to install a ramp or elevator....
-
Circulation Path
An exterior or interior way of passage provided for pedestrian travel, including but not limited to, walks, hallways, courtyards, elevators, platform lifts, ramps, stairways, and landings...
-
E1-3. Route Level Changes
Does the route from the accessible entrance to the voting area change levels using a ramp, lift or elevator? Yes _____ No _____ If no, go to question E1-7....
-
4(6)
The finished surface of this area that is located immediately outside the entry may be sloped, up to 1/8 inch per foot (12 inches), for drainage. ...
-
404.2.5 Thresholds
EXCEPTION: Existing or altered thresholds 3/4 inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply with 404.2.5...
-
K) Temporary Events
Selected Accessible Features of Town Fair • temporary curb ramp added where needed to provide an accessible route • booths and vendors located on an accessible route • sign language...
- SciFit Inclusive Fitness PRO1 - Upper Body Machine
-
PRIORITIES
These measures include, for example, installing an entrance ramp, widening entrances, and providing accessible parking spaces....
-
§382.97(c)
(c) Any other aircraft model determined by the Department of Transportation to be unsuitable for boarding and deplaning assistance by lift, ramp, or other suitable device....
-
§27.75(a)(3)(ii)
(ii) It would be infeasible for mobility-limited persons to reach the over-passes, under-passes or ramps because of unusual topographical or architectural obstacles unrelated to the federally...
-
Scoping [4.1.2(4), 4.1.3(3)]
Requirements in 4.5 apply to accessible routes and spaces, including ramps, elevators, platform lifts, and clear floor space....
-
Transfer Access [1014.2.1]
When the surface of the clear ground space is constructed of asphalt, concrete, or boards, the slope of the clear ground space must be no steeper than 1:48 (2 percent) in any direction....
-
F206.7.5 Existing Site Constraints
Platform lifts shall be permitted where existing exterior site constraints make use of a ramp or elevator infeasible. Advisory F206.7.5 Existing Site Constraints....
-
206.7.5 Existing Site Constraints
Platform lifts shall be permitted where existing exterior site constraints make use of a ramp or elevator technically infeasible. Advisory 206.7.5 Existing Site Constraints....
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
11B-404.2.5 Thresholds
[2010 ADAS] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply...
-
1009.4.1 Clear Deck Space
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
R408.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
4.7.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
Post-Mounted Objects [§307.3]
The 12” limit also applies to the clearance between multiple posts (excluding the sloping portions of handrails)....
-
Thresholds [§404.2.5]
A maximum height of 3/4” is permitted for existing or altered thresholds if they have a beveled edge on each side with a slope not steeper than 1:2....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-404.2.5 Thresholds
[2010 ADAS] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply...