General Substantive Requirements of the New Construction Provisions (Section-By-Section Analysis and Response to Comments)
-
11B-246.2 Camping facilities
at least two campsites and one additional campsite for each 100 campsites or fraction thereof, shall be accessed by and connected to sanitary facilities by travel routes with a maximum slope...
-
4.1.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface slope, size, or location, the...
-
11B-246.2 Camping facilities
at least two campsites and one additional campsite for each 100 campsites or fraction thereof, shall be accessed by and connected to sanitary facilities by travel routes with a maximum slope...
-
11B-246.2 Camping facilities
at least two campsites and one additional campsite for each 100 campsites or fraction thereof, shall be accessed by and connected to sanitary facilities by travel routes with a maximum slope...
- UMEA Waste Receptacle
-
Introduction
Curb ramps providing access to streets and sidewalks are a basic city service....
-
What Contributes to the Determination of "Readily Achievable"?
Never exceeds the new construction requirements The Department's regulation contains a list of 21 examples of modifications that may be readily achievable: 1) Installing ramps...
-
T503.5 Exterior Illumination for Boarding and Alighting Areas
Where doorways have ramps, bridgeplates or lifts, the illumination shall be 1 foot-candle (11 lux) minimum for a distance of 3 feet (915 mm) measured beyond the edge of the ramp, bridgeplate...
-
505.10.3 Bottom Extension at Stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
-
T302.4 Surface Discontinuities
Surface discontinuities shall be ½ inch (13 mm) high maximum and shall be beveled with a slope not steeper than 1:2. EXCEPTIONS: 1....
-
Bus boarding and alighting areas
be in compliance with the ADA-ABA Guidelines (Section 810.2), which address surfaces (sturdy), dimensions (96" long x 60" wide); connection to sidewalks, streets and pedestrian paths; slope...
-
1009.2.2 Seat Location
The deck surface between the centerline of the seat and the pool edge shall have a slope not steeper than 1:48. Figure 1009.2.2 Pool Lift Seat Location...
- Willoughby Industries ASHS-1013-06-15-HC Ligature-Resistant 15" wide Lavatory
- Sargent 8200 Mortise Lock with BHL Trim
-
Passing Spaces [1016.4]
When passing spaces and resting intervals overlap, the technical requirements for resting intervals apply and the slope of the surface must be no steeper than 1:48 (2 percent) in any direction...
-
§35.151 New Construction and Alterations
In response to comments, the Department has added to the final rule a new paragraph (e) setting out the requirements of § 36.151 as applied to curb ramps....
-
§35.151 New construction and alterations. (Section-by-Section Analysis)
In response to comments, the Department has added to the final rule a new paragraph (e) setting out the requirements of §36.151 as applied to curb ramps....
-
11B-1008.2.3 Water play components
route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with Sections 11B-302 _|Floor or Ground Surfaces|_, 11B-403.3, 11B-405.2 _|Slope...
-
11B-504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
Treads and Risers [4.9.2], Nosings [4.9.3]
Angled or rounded nosings or sloped risers help prevent this hazard and provide a smoother transition. Straight risers without nosings are acceptable....
-
F216.13 Trailhead Signs
requirements in 1017.11 require the signs to include information on the length of the trail or trail segment; surface type; typical and minimum tread width; typical and minimum running slope...
-
11B-504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
11B-1008.2.3 Water play components
route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with Sections 11B-302 _|Floor or Ground Surfaces|_, 11B-403.3, 11B-405.2 _|Slope...